Philippines Fiber Optics

Connect the people, connect the world ...

Fiber Optic Cables

Dell AOC-Q28DD-2Q28-100G-7M Compatible 200G QSFP-DD 8 x 25G NRZ to 2 x 100G QSFP28 4 x 25G NRZ Active Optical Breakout Cable, 7m (23ft)

Dell AOC-Q28DD-2Q28-100G-7M Compatible 200G QSFP-DD 8 x 25G NRZ to 2 x 100G QSFP28 4 x 25G NRZ Active Optical Breakout Cable, 7m (23ft)

The AOC-Q28DD-2Q28-100G-7M compatible assembly addresses a specific interoperability requirement: Dell host identification on a 200G AOC link measuring 7m (23ft). Its interface configuration is QSFP-DD to 2x 100G QSFP28. This page explains the physical product, port-configuration checks and related part numbers so selection does not rely on connector appearance alone.

OEM Part Number: AOC-Q28DD-2Q28-100G-7MHT Part Number: AOC-Q28DD-2Q28-100G-7M

Product Highlights

  • Compatible alternative to Dell AOC-Q28DD-2Q28-100G-7M
  • 200G connectivity at 200Gbps
  • Interface configuration: QSFP-DD to 2x 100G QSFP28
  • Fixed length and part number: 7m (23ft), AOC-Q28DD-2Q28-100G-7M
  • Cable construction: OM3
  • Maximum power consumption: 4W (QSFP-DD End) 2.5W (QSFP28 Per End)
  • Minimum bend radius: 30mm
  • Operating temperature: 0 to 70°C (32 to 158°F)

Specifications

HT Part NumberAOC-Q28DD-2Q28-100G-7M
Dell CompatibleAOC-Q28DD-2Q28-100G-7M
ManufacturerHT
Form FactorQSFP-DD to 2x 100G QSFP28
Max. Data Rate200Gbps
Cable Length7m (23ft)
Cable TypeOM3
Wavelength850nm
Minimum Bend Radius30mm
Transmitter TypeVSCEL
Receiver TypePIN
Max. Power Consumption4W (QSFP-DD End) 2.5W (QSFP28 Per End)
Jacket MaterialOFNP
CDR (Clock and Data Recovery)Not Supported
Modulation FormatNRZ
Commercial Temperature Range0 to 70°C (32 to 158°F)
ProtocolsQSFP-DD MSA V5.0, QSFP28 MSA, CMIS V4.0, SFF-8636

Signal and Lane Configuration

The listed modulation format is NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Cable Construction and Routing

This assembly uses OFNP jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include QSFP-DD MSA V5.0, QSFP28 MSA, CMIS V4.0, SFF-8636. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The QSFP-DD to 2x 100G QSFP28 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Integrated Optical Assembly

The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.

Length Selection and Installation Planning

Measure twice before deploying this 7m (23ft) cable: once along the planned route and again after accounting for service access. The objective is adequate reach without a concealed surplus. Support the integrated optical cable and both optical engines, preserve front-panel clearance and check that nearby power cords or sharp hardware cannot damage the jacket. Within this family, AOC-Q28DD-2Q28-100G-5M is shorter at 5m (16ft), while AOC-Q28DD-2Q28-100G-10M is the next longer choice at 10m (33ft); comparing those two boundaries helps avoid both tension and unnecessary slack.

Position Within the Length Range

AOC-Q28DD-2Q28-100G-7M occupies the middle of this family between AOC-Q28DD-2Q28-100G-5M at 5m (16ft) and AOC-Q28DD-2Q28-100G-10M at 10m (33ft). It adds 2m over the shorter option for extra routing clearance, while the next longer version adds another 3m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Interoperability and Configuration Checks

Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the minimum bend radius is 30mm; the stated power consumption is 4W (QSFP-DD End) 2.5W (QSFP28 Per End); the jacket material is OFNP.

Power and Thermal Planning

The rated power consumption is 4W (QSFP-DD End) 2.5W (QSFP28 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Ordering Information

Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. Keep AOC-Q28DD-2Q28-100G-7M associated with 7m (23ft) throughout the order and receiving record.

Dell Compatibility and Factory Testing

The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. Where supported by the host, receive activity and diagnostic indications are reviewed together with the established link.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.

Quality Assurance and Packaging

Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Standard protective packing is used by default, with project documentation arranged when requested.

Frequently Asked Questions

Is this an original Dell cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies Dell AOC-Q28DD-2Q28-100G-7M.

What details assist a compatibility review?

Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.

How should an unused assembly be stored?

Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.

Can different brands be connected with the same assembly?

Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.


About us

China Factory:No 168 Golden Ground Industrial Area;
Philippines Address:Makati City,Metro Manila, Philippines

Products catalogues

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

Customer Support