Projects in the Philippines benefit from keeping the configuration, branch identification and installation requirement consistent across every participating site. The customized MMC-16 trunk is an OS2 backbone item built around MMC connectors based on sixteen-fiber sub-units. Fiber capacity may scale from 16 to 384 fibers, with cable outside diameter from 4.0 to 17.5mm depending on the chosen design. G.657.A1 glass, APC polish and an OFNP jacket give the foundation for project-specific single-mode distribution.
| Part Number | XXMMCSMF |
|---|---|
| Manufacturer | HT |
| Connector A | US Conec MMC |
| Connector B | US Conec MMC |
| Polish Type | APC to APC |
| Glass Fiber | G.657.A1 |
| Fiber Mode | OS2 9/125μm |
| Wavelength | 1310/1550nm |
| Fiber Count | 16-384 Fibers |
| Polarity | Trunk/ Extender Polarity |
| Cable Outside Diameter (OD) | 4.0-17.5mm |
| Cable Jacket | Plenum (OFNP) |
| Min. Bend Radius (Optical Fiber) | 10mm |
| Min. Bend Radius (Fiber Cable) | 20/10D (Dynamic/Static) |
| Tensile Strength (Long Term) | 200-400N |
| Tensile Strength (Short Term) | 660-1320N |
| Insertion Loss | ≤0.35dB |
| Return Loss | ≥60dB |
| Attenuation at 1310nm | ≤0.35dB/km |
| Attenuation at 1550nm | ≤0.21dB/km |
| Operating Temperature | -10 to 60°C (14 to 140℉) |
| Storage Temperature | -10 to 70°C (14 to 158℉) |
A trunk should not be treated as only a longer jumper. As fiber count increases, sub-unit arrangement, cable diameter, pulling strength and breakout protection become part of the design. This MMC-16 product line supports trunk or extender polarity and 200–400N long-term tensile ratings, with 660–1320N short-term ratings across the design range. The particular values suitable to an order should ideally be confirmed on its production layout.
Typical uses state links between optical distribution frames, equipment rows and space-efficient MMC panels. Pre-termination allows several fibers to be installed in one pull and tested before arrival. The rack schedule should identify every sub-unit, connector polarity and gender transition so this backbone cable lands correctly. High fiber counts additionally require enough rear cable management and static bend space.
There is no assumed stock length for this customized product. List the channel length in feet or meters, total fiber count, MMC connector gender, polarity, breakout lengths, jacket criteria and labeling. Pulling eyes or other deployment protection may readily be discussed where the pathway requires them. Length, diameter and tensile design are confirmed as one system rather than chosen on its own.
Use XXMMCSMF as the MMC-16 trunk product line reference and attach a fiber plan or layout. A useful inquiry includes polarity, deployment conditions, length, fiber count, sub-unit mapping and connector gender, allowing the factory to quote the right engineered item. Customers in the Philippines can include multi-site labeling or documentation requirements when requesting a project quotation.