Projects in the Philippines benefit from keeping the configuration, branch identification and installation requirement consistent across every participating site. This customized MMC-24 trunk uses 24-fiber MMC sub-units to create OS2 backbone assemblies from 24 to 576 fibers. Depending on design, the fiber cable outside diameter ranges from 4.0 to 18.0mm. APC interfaces, G.657.A1 bend-insensitive glass and plenum jacketing suit high-capacity single-mode links where deployment time and panel density are key design constraints.
| Part Number | XXMMCSMF |
|---|---|
| Manufacturer | HT |
| Connector A | US Conec MMC |
| Connector B | US Conec MMC |
| Polish Type | APC to APC |
| Glass Fiber | G.657.A1 |
| Fiber Mode | OS2 9/125μm |
| Wavelength | 1310/1550nm |
| Fiber Count | 24-576 Fibers |
| Polarity | Trunk/ Extender Polarity |
| Cable Outside Diameter (OD) | 4.0-18.0mm |
| Cable Jacket | Plenum (OFNP) |
| Min. Bend Radius (Optical Fiber) | 10mm |
| Min. Bend Radius (Fiber Cable) | 20/10D (Dynamic/Static) |
| Tensile Strength (Long Term) | 200-400N |
| Tensile Strength (Short Term) | 660-1320N |
| Insertion Loss | ≤0.35dB |
| Return Loss | ≥60dB |
| Attenuation at 1310nm | ≤0.35dB/km |
| Attenuation at 1550nm | ≤0.21dB/km |
| Operating Temperature | -10 to 60°C (14 to 140℉) |
| Storage Temperature | -10 to 70°C (14 to 158℉) |
MMC-24 design concentrates more fibers into each multi-fiber mounting point than MMC-16, which may reduce the number of sub-units in a large backbone. It additionally changes the fiber assignment at every termination. The connected panels and equipment patch leads should be suited to the equivalent 24-fiber organization; otherwise a 24-fiber trunk cannot be made compatible only by changing a label or adapter.
Across the customizable range, long-term tensile strength is 200–400N and short-term strength is 660–1320N, but the suitable design is governed by fiber count. A 576-fiber channel needs separate handling from a 24-fiber cord. Plan tray fill, pulling access, reel handling and the 20/10D dynamic/static bend criteria before selecting the final cable design.
No fixed standard length is assigned to this trunk. Orders are built to the applicable meter or foot length and may use trunk or extender polarity. Give the number of 24-fiber sub-units, connector gender, fan-out dimensions and identification scheme. The 4.0–18.0mm diameter range and fiber-count maximum are product line boundaries, not a promise that every combination has the equivalent design.
Reference XXMMCSMF for the MMC-24 trunk product line and submit the applicable length, total fiber count and port map. Our support staff may then validate diameter, sub-unit arrangement, pulling criteria and tags before manufacturing the backbone. Customers in the Philippines can include multi-site labeling or documentation requirements when requesting a project quotation.