Philippines Fiber Optics

Connect the people, connect the world ...

Fiber Optic Cables

NVIDIA/Mellanox MCA7J65-N002 Compatible 800G Twin-port OSFP 8 x 100G PAM4 IHS/Finned Top to 2 x 400G QSFP112 4 x 100G PAM4 InfiniBand NDR Active Copper Breakout Cable, 2m (7ft)

NVIDIA/Mellanox MCA7J65-N002 Compatible 800G Twin-port OSFP 8 x 100G PAM4 IHS/Finned Top to 2 x 400G QSFP112 4 x 100G PAM4 InfiniBand NDR Active Copper Breakout Cable, 2m (7ft)

Use this 2m (7ft) ACC cable for hosts expecting NVIDIA/Mellanox MCA7J65-N002 and a 800G direct-attached interface. The assembly uses OSFP (IHS/Finned Top) to 2x QSFP112; lane, protocol and breakout considerations are documented alongside the verified table. Every alternative length remains a separate order code with its own technical page.

OEM Part Number: MCA7J65-N002HT Part Number: MCA7J65-N002

Product Highlights

  • Compatible alternative to NVIDIA/Mellanox MCA7J65-N002
  • 800G connectivity at 850Gbps (8x 106.25Gbps)
  • Interface configuration: OSFP (IHS/Finned Top) to 2x QSFP112
  • Fixed length and part number: 2m (7ft), MCA7J65-N002
  • Cable construction: Active Breakout DAC (ACC)
  • Conductor specification: 30AWG
  • Maximum power consumption: 1.5W (OSFP End)0.6W (QSFP112 Per End)
  • Minimum bend radius: 32.5mm

Specifications

HT Part NumberMCA7J65-N002
NVIDIA/Mellanox InfiniBand CompatibleMCA7J65-N002
ManufacturerHT
Form FactorOSFP (IHS/Finned Top) to 2x QSFP112
Max. Data Rate850Gbps (8x 106.25Gbps)
MediaCopper
Cable TypeActive Breakout DAC (ACC)
Cable Length2m (7ft)
Wire AWG30AWG
Minimum Bend Radius32.5mm
Max. Power Consumption1.5W (OSFP End)0.6W (QSFP112 Per End)
Jacket MaterialPET
Commercial Temperature Range0 to 70°C (32 to 158°F)
Modulation Format8x100G-PAM4 to Dual 4x100G-PAM4
Application800G/400G InfiniBand
ProtocolsCMIS 5.0, IEEE 802.3ck, OSFP MSA Rev5.0, Q112 MSA

Signal and Lane Configuration

The listed modulation format is 8x100G-PAM4 to Dual 4x100G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Power and Thermal Planning

The rated power consumption is 1.5W (OSFP End)0.6W (QSFP112 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 30AWG conductors, PET jacket, minimum bend radius 32.5mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is 800G/400G InfiniBand. Listed interface and protocol references include CMIS 5.0, IEEE 802.3ck, OSFP MSA Rev5.0, Q112 MSA. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The OSFP (IHS/Finned Top) to 2x QSFP112 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Length Selection and Installation Planning

MCA7J65-N002 provides 2m (7ft) for connections between separated rack units or nearby equipment positions. Plan the route around cable managers and power cords, keeping the assembly free from connector strain while avoiding a large obstruction in the airflow path.

Position Within the Length Range

MCA7J65-N002 occupies the middle of this family between MCA7J65-N001 at 1m (3ft) and MCA7J65-N003 at 3m (10ft). It adds 1m over the shorter option for extra routing clearance, while the next longer version adds another 1m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Interoperability and Configuration Checks

Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 32.5mm; the stated power consumption is 1.5W (OSFP End)0.6W (QSFP112 Per End); the jacket material is PET.

Ordering Information

Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. Quantity and any labeling instructions should be attached specifically to MCA7J65-N002.

NVIDIA/Mellanox Compatibility and Factory Testing

The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.

Quality Assurance and Packaging

Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Neutral packaging and customer-specific packing documentation are available on request.

Frequently Asked Questions

Is this an original NVIDIA/Mellanox cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies NVIDIA/Mellanox MCA7J65-N002.

How should an unused assembly be stored?

Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.

Can different brands be connected with the same assembly?

Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.

Does this order code cover multiple lengths?

No. MCA7J65-N002 refers here to 2m (7ft). Every other verified length has a separate part number and page in the length list.


About us

China Factory:No 168 Golden Ground Industrial Area;
Philippines Address:Makati City,Metro Manila, Philippines

Products catalogues

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

Customer Support

For customer support, please email sales@huihongfiber.com; our support team will get back to you as soon as possible.