A successful 800G link depends on host acceptance as well as physical fit. This MCA7J65-N005 compatible ACC assembly combines OSFP (IHS/Finned Top) to 2x QSFP112 with a fixed 5m (16ft) cable for NVIDIA/Mellanox equipment. The specifications, configuration guidance and live-link factory verification below describe the exact product supplied under this reference.
OEM Part Number: MCA7J65-N005HT Part Number: MCA7J65-N005
| HT Part Number | MCA7J65-N005 |
|---|---|
| NVIDIA/Mellanox InfiniBand Compatible | MCA7J65-N005 |
| Manufacturer | HT |
| Form Factor | OSFP (IHS/Finned Top) to 2x QSFP112 |
| Max. Data Rate | 850Gbps (8x 106.25Gbps) |
| Media | Copper |
| Cable Type | Active Breakout DAC (ACC) |
| Cable Length | 5m (16ft) |
| Wire AWG | 26AWG |
| Minimum Bend Radius | 40mm |
| Max. Power Consumption | 1.5W (OSFP End)0.6W (QSFP112 Per End) |
| Jacket Material | PET |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Modulation Format | 8x100G-PAM4 to Dual 4x100G-PAM4 |
| Application | 800G/400G InfiniBand |
| Protocols | CMIS 5.0, IEEE 802.3ck, OSFP MSA Rev5.0, Q112 MSA |
The listed modulation format is 8x100G-PAM4 to Dual 4x100G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the listed conductor specification is 26AWG; the minimum bend radius is 40mm; the stated power consumption is 1.5W (OSFP End)0.6W (QSFP112 Per End); the jacket material is PET.
The rated power consumption is 1.5W (OSFP End)0.6W (QSFP112 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
This assembly uses 26AWG conductors, PET jacket, minimum bend radius 40mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is 800G/400G InfiniBand. Listed interface and protocol references include CMIS 5.0, IEEE 802.3ck, OSFP MSA Rev5.0, Q112 MSA. Confirm that the host firmware and port configuration support the same operating mode.
The OSFP (IHS/Finned Top) to 2x QSFP112 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
The 5m (16ft) length gives MCA7J65-N005 more freedom for adjacent-rack and row-end deployments. Longer copper runs need particular attention to routing weight and bend control; the ACC specification and host support must still match the intended link.
MCA7J65-N005 is the longest of 4 verified length options in this family. Compared with MCA7J65-N003 at 3m (10ft), it provides 2m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.
Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. Quantity and any labeling instructions should be attached specifically to MCA7J65-N005.
The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. Where supported by the host, link stability and diagnostic indications are reviewed together with the established link.
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.
Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Neutral packaging and customer-specific packing documentation are available on request.
No. It is an HT-manufactured compatible alternative for equipment that specifies NVIDIA/Mellanox MCA7J65-N005.
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.