Use this 1.1m (3.6ft) ACC cable for hosts expecting Generic OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-1.6T-ACC-1.1M3.6FT and a 1.6T direct-attached interface. The assembly uses OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top); lane, protocol and breakout considerations are documented alongside the verified table. Every alternative length remains a separate order code with its own technical page.
OEM Part Number: OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-1.6T-ACC-1.1M3.6FTHT Part Number: OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-1.6T-ACC-1.1M3.6FT
| HT Part Number | OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-1.6T-ACC-1.1M3.6FT |
|---|---|
| Manufacturer | HT |
| Form Factor | OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top) |
| Max. Data Rate | 1600Gbps |
| Media | Copper |
| Cable Type | Active DAC (ACC) |
| Cable Length | 1.1m (3.6ft) |
| Jacket Material | PET |
| Minimum Bend Radius | 50mm |
| Wire AWG | 30AWG |
| Max. Power Consumption | 2W Per End |
| Modulation Format | 8x 200G-PAM4 to 8x 200G-PAM4 |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Application | 1.6T Ethernet |
| Protocols | OSFP Rev 5.2, IEEE 802.3df, IEEE 802.3dj, CMIS 5.0 |
The listed modulation format is 8x 200G-PAM4 to 8x 200G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
The intended application is 1.6T Ethernet. Listed interface and protocol references include OSFP Rev 5.2, IEEE 802.3df, IEEE 802.3dj, CMIS 5.0. Confirm that the host firmware and port configuration support the same operating mode.
The additional half metre beyond a one-metre assembly gives OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-1.6T-ACC-1.1M3.6FT useful routing flexibility when the ports are not directly aligned. It can accommodate a different rack unit or a short service loop, but excess cable should be dressed loosely rather than folded into a tight coil.
OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-1.6T-ACC-1.1M3.6FT is the shortest of 3 verified length options in this family. It is the preferred choice when the port positions are close and cable slack must be kept to a minimum. The next option is OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-1.6T-ACC-1.5M5FT at 1.5m (5ft), adding 0.4m for a less direct routing path; selecting it unnecessarily would leave more cable to dress.
Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 50mm; the stated power consumption is 2W Per End; the jacket material is PET.
The rated power consumption is 2W Per End. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
This assembly uses 30AWG conductors, PET jacket, minimum bend radius 50mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. Quantity and any labeling instructions should be attached specifically to OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-1.6T-ACC-1.1M3.6FT.
The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. Both connectors are examined before the operating test, which includes link stability and diagnostic indications.
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.
Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Volume orders can include customer references on the labels and carton list.
No. It is manufactured by HT under our own manufacturer identity.
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.