Philippines Fiber Optics

Connect the people, connect the world ...

Fiber Optic Cables

OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-1.6T-ACC-1.5M5FT 1.6T OSFP224 8 x 200G PAM4 IHS/Finned Top Active Copper Twinax Cable, 1.5m (5ft)

OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-1.6T-ACC-1.5M5FT 1.6T OSFP224 8 x 200G PAM4 IHS/Finned Top Active Copper Twinax Cable, 1.5m (5ft)

Use this 1.5m (5ft) ACC cable for hosts expecting Generic OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-1.6T-ACC-1.5M5FT and a 1.6T direct-attached interface. The assembly uses OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top); lane, protocol and breakout considerations are documented alongside the verified table. Every alternative length remains a separate order code with its own technical page.

OEM Part Number: OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-1.6T-ACC-1.5M5FTHT Part Number: OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-1.6T-ACC-1.5M5FT

Product Highlights

  • HT-manufactured ACC assembly in 1.5m (5ft)
  • 1.6T connectivity at 1600Gbps
  • Interface configuration: OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)
  • Fixed length and part number: 1.5m (5ft), OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-1.6T-ACC-1.5M5FT
  • Cable construction: Active DAC (ACC)
  • Conductor specification: 30AWG
  • Maximum power consumption: 2W Per End
  • Minimum bend radius: 50mm

Specifications

HT Part NumberOSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-1.6T-ACC-1.5M5FT
ManufacturerHT
Form FactorOSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)
Max. Data Rate1600Gbps
MediaCopper
Cable TypeActive DAC (ACC)
Cable Length1.5m (5ft)
Jacket MaterialPET
Minimum Bend Radius50mm
Wire AWG30AWG
Max. Power Consumption2W Per End
Modulation Format8x 200G-PAM4 to 8x 200G-PAM4
Commercial Temperature Range0 to 70°C (32 to 158°F)
Application1.6T Ethernet
ProtocolsOSFP Rev 5.2, IEEE 802.3df, IEEE 802.3dj, CMIS 5.0

Signal and Lane Configuration

The listed modulation format is 8x 200G-PAM4 to 8x 200G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Interoperability and Configuration Checks

Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 50mm; the stated power consumption is 2W Per End; the jacket material is PET.

Power and Thermal Planning

The rated power consumption is 2W Per End. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 30AWG conductors, PET jacket, minimum bend radius 50mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is 1.6T Ethernet. Listed interface and protocol references include OSFP Rev 5.2, IEEE 802.3df, IEEE 802.3dj, CMIS 5.0. Confirm that the host firmware and port configuration support the same operating mode.

Length Selection and Installation Planning

The additional half metre beyond a one-metre assembly gives OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-1.6T-ACC-1.5M5FT useful routing flexibility when the ports are not directly aligned. It can accommodate a different rack unit or a short service loop, but excess cable should be dressed loosely rather than folded into a tight coil.

Position Within the Length Range

OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-1.6T-ACC-1.5M5FT occupies the middle of this family between OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-1.6T-ACC-1.1M3.6FT at 1.1m (3.6ft) and OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-1.6T-ACC-2M7FT at 2m (7ft). It adds 0.4m over the shorter option for extra routing clearance, while the next longer version adds another 0.5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Ordering Information

Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. Keep OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-1.6T-ACC-1.5M5FT associated with 1.5m (5ft) throughout the order and receiving record.

Generic Compatibility and Factory Testing

The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. Both connectors are examined before the operating test, which includes link stability and diagnostic indications.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.

Quality Assurance and Packaging

Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Volume orders can include customer references on the labels and carton list.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

What details assist a compatibility review?

Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.

How should an unused assembly be stored?

Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.

Can different brands be connected with the same assembly?

Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.


About us

China Factory:No 168 Golden Ground Industrial Area;
Philippines Address:Makati City,Metro Manila, Philippines

Products catalogues

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

Customer Support

For customer support, please email sales@huihongfiber.com; our support team will get back to you as soon as possible.