Philippines Fiber Optics

Connect the people, connect the world ...

Fiber Optic Cables

OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-AOC-25M82FT 400G OSFP 8 x 50G PAM4 IHS/Finned Top Ethernet Active Optical Cable, 25m (82ft)

OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-AOC-25M82FT 400G OSFP 8 x 50G PAM4 IHS/Finned Top Ethernet Active Optical Cable, 25m (82ft)

Use this 25m (82ft) AOC cable for hosts expecting Generic OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-AOC-25M82FT and a 400G direct-attached interface. The assembly uses OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top); lane, protocol and breakout considerations are documented alongside the verified table. Every alternative length remains a separate order code with its own technical page.

OEM Part Number: OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-AOC-25M82FTHT Part Number: OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-AOC-25M82FT

Product Highlights

  • HT-manufactured AOC assembly in 25m (82ft)
  • 400G connectivity at 400Gbps
  • Interface configuration: OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)
  • Fixed length and part number: 25m (82ft), OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-AOC-25M82FT
  • Cable construction: Active Optical Cable
  • Maximum power consumption: 10W Per End
  • Minimum bend radius: 30mm
  • Operating temperature: 0 to 70°C (32 to 158°F)

Specifications

HT Part NumberOSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-AOC-25M82FT
ManufacturerHT
Form FactorOSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)
Max. Data Rate400Gbps
Cable Length25m (82ft)
Cable TypeActive Optical Cable
Wavelength850nm
Minimum Bend Radius30mm
Transmitter TypeVCSEL
Receiver TypePIN
Max. Power Consumption10W Per End
Modulation Format8x 50G-PAM4
CDR (Clock and Data Recovery)TX & RX Built-in CDR
Jacket MaterialOFNP
DDM/DOMSupported
Commercial Temperature Range0 to 70°C (32 to 158°F)
Inbuilt FECYes
Application400G Ethernet
ProtocolsCMIS V4.0, OSFP MSA

Signal and Lane Configuration

The listed modulation format is 8x 50G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Length Selection and Installation Planning

With 25m (82ft) available, the installer has more routing freedom but also more cable to control. Determine where any remaining service loop will be stored, preserve the stated bend radius and keep the loop away from sharp edges and hot exhaust. The integrated optical cable and both optical engines should remain accessible for inspection and removal. Within this family, OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-AOC-20M66FT is shorter at 20m (66ft), while OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-AOC-30M98FT is the next longer choice at 30m (98ft); comparing those two boundaries helps avoid both tension and unnecessary slack.

Position Within the Length Range

OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-AOC-25M82FT occupies the middle of this family between OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-AOC-20M66FT at 20m (66ft) and OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-AOC-30M98FT at 30m (98ft). It adds 5m over the shorter option for extra routing clearance, while the next longer version adds another 5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Interoperability and Configuration Checks

Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the minimum bend radius is 30mm; the stated power consumption is 10W Per End; the jacket material is OFNP.

Power and Thermal Planning

The rated power consumption is 10W Per End. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses OFNP jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is 400G Ethernet. Listed interface and protocol references include CMIS V4.0, OSFP MSA. Confirm that the host firmware and port configuration support the same operating mode.

Integrated Optical Assembly

The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.

Ordering Information

Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. Quantity and any labeling instructions should be attached specifically to OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-AOC-25M82FT.

Generic Compatibility and Factory Testing

The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. The check includes receive activity and diagnostic indications, followed by a final inspection of both ends.

Shipping and Lead Time

Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.

Quality Assurance and Packaging

Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Standard protective packing is used by default, with project documentation arranged when requested.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.

What details assist a compatibility review?

Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.

How should an unused assembly be stored?

Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.


About us

China Factory:No 168 Golden Ground Industrial Area;
Philippines Address:Makati City,Metro Manila, Philippines

Products catalogues

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

Customer Support

For customer support, please email sales@huihongfiber.com; our support team will get back to you as soon as possible.