
A successful 400G link depends on host acceptance as well as physical fit. This OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-AOC-7M23FT compatible AOC assembly combines OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top) with a fixed 7m (23ft) cable for Generic equipment. The specifications, configuration guidance and live-link factory verification below describe the exact product supplied under this reference.
OEM Part Number: OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-AOC-7M23FTHT Part Number: OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-AOC-7M23FT
| HT Part Number | OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-AOC-7M23FT |
|---|---|
| Manufacturer | HT |
| Form Factor | OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top) |
| Max. Data Rate | 400Gbps |
| Cable Length | 7m (23ft) |
| Cable Type | Active Optical Cable |
| Wavelength | 850nm |
| Minimum Bend Radius | 30mm |
| Transmitter Type | VCSEL |
| Receiver Type | PIN |
| Max. Power Consumption | 10W Per End |
| Modulation Format | 8x 50G-PAM4 |
| CDR (Clock and Data Recovery) | TX & RX Built-in CDR |
| Jacket Material | OFNP |
| DDM/DOM | Supported |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Inbuilt FEC | Yes |
| Application | 400G Ethernet |
| Protocols | CMIS V4.0, OSFP MSA |
The listed modulation format is 8x 50G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the minimum bend radius is 30mm; the stated power consumption is 10W Per End; the jacket material is OFNP.
The rated power consumption is 10W Per End. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
This assembly uses OFNP jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is 400G Ethernet. Listed interface and protocol references include CMIS V4.0, OSFP MSA. Confirm that the host firmware and port configuration support the same operating mode.
The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.
This 7m (23ft) assembly is intended for routes that shorter members of the same family cannot serve comfortably. Before ordering, document the actual pathway and the space available for service access. During installation, secure the integrated optical cable and both optical engines without compressing it into an undersized bundle or leaving its weight suspended from the ports. Within this family, OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-AOC-5M16FT is shorter at 5m (16ft), while OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-AOC-10M33FT is the next longer choice at 10m (33ft); comparing those two boundaries helps avoid both tension and unnecessary slack.
OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-AOC-7M23FT occupies the middle of this family between OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-AOC-5M16FT at 5m (16ft) and OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-AOC-10M33FT at 10m (33ft). It adds 2m over the shorter option for extra routing clearance, while the next longer version adds another 3m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. Quantity and any labeling instructions should be attached specifically to OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-AOC-7M23FT.
The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. The check includes receive activity and diagnostic indications, followed by a final inspection of both ends.
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.
Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Volume orders can include customer references on the labels and carton list.
No. It is manufactured by HT under our own manufacturer identity.
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.