
The QDD-400-CU2M compatible assembly addresses a specific interoperability requirement: Cisco host identification on a 400G DAC link measuring 2m (7ft). Its interface configuration is QSFP-DD to QSFP-DD. This page explains the physical product, port-configuration checks and related part numbers so selection does not rely on connector appearance alone.
OEM Part Number: QDD-400-CU2MHT Part Number: QDD-400-CU2M
| HT Part Number | QDD-400-CU2M |
|---|---|
| Cisco Compatible | QDD-400-CU2M |
| Manufacturer | HT |
| Form Factor | QSFP-DD to QSFP-DD |
| Max. Data Rate | 400Gbps |
| Media | Copper |
| Cable Type | Passive Twinax |
| Cable Length | 2m (7ft) |
| Wire AWG | 28AWG |
| Minimum Bend Radius | 39.5mm |
| Max. Power Consumption | 0.1W Per End |
| Jacket Material | PET (OFNR) |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Modulation Format | 8x 50Gbps PAM4 |
| Application | 400G Ethernet |
| Protocols | IEEE 802.3cd, QSFP-DD MSA, CMIS 4.0 |
The listed modulation format is 8x 50Gbps PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
QDD-400-CU2M provides 2m (7ft) for connections between separated rack units or nearby equipment positions. Plan the route around cable managers and power cords, keeping the assembly free from connector strain while avoiding a large obstruction in the airflow path.
QDD-400-CU2M occupies the middle of this family between QDD-400-CU1.5M at 1.5m (5ft) and QDD-400-CU2.5M at 2.5m (8ft). It adds 0.5m over the shorter option for extra routing clearance, while the next longer version adds another 0.5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the listed conductor specification is 28AWG; the minimum bend radius is 39.5mm; the stated power consumption is 0.1W Per End; the jacket material is PET (OFNR).
The rated power consumption is 0.1W Per End. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
This assembly uses 28AWG conductors, PET (OFNR) jacket, minimum bend radius 39.5mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is 400G Ethernet. Listed interface and protocol references include IEEE 802.3cd, QSFP-DD MSA, CMIS 4.0. Confirm that the host firmware and port configuration support the same operating mode.
A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.
Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. Keep QDD-400-CU2M associated with 2m (7ft) throughout the order and receiving record.
The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. Where supported by the host, link stability and diagnostic indications are reviewed together with the established link.
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.
Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Standard protective packing is used by default, with project documentation arranged when requested.
No. It is an HT-manufactured compatible alternative for equipment that specifies Cisco QDD-400-CU2M.
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.
Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.
Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.