Cisco QDD-400-CU3M Compatible 400G QSFP-DD 8 x 50G PAM4 Passive Copper Twinax Cable, 3m (10ft)

Cisco QDD-400-CU3M Compatible 400G QSFP-DD 8 x 50G PAM4 Passive Copper Twinax Cable, 3m (10ft)

Use this 3m (10ft) DAC cable for hosts expecting Cisco QDD-400-CU3M and a 400G direct-attached interface. The assembly uses QSFP-DD to QSFP-DD; lane, protocol and breakout considerations are documented alongside the verified table. Every alternative length remains a separate order code with its own technical page.

OEM Part Number: QDD-400-CU3MHT Part Number: QDD-400-CU3M

Product Highlights

  • Compatible alternative to Cisco QDD-400-CU3M
  • 400G connectivity at 400Gbps
  • Interface configuration: QSFP-DD to QSFP-DD
  • Fixed length and part number: 3m (10ft), QDD-400-CU3M
  • Cable construction: Passive Twinax
  • Conductor specification: 26AWG
  • Maximum power consumption: 0.1W Per End
  • Minimum bend radius: 57mm

Specifications

HT Part NumberQDD-400-CU3M
Cisco CompatibleQDD-400-CU3M
ManufacturerHT
Form FactorQSFP-DD to QSFP-DD
Max. Data Rate400Gbps
MediaCopper
Cable TypePassive Twinax
Cable Length3m (10ft)
Wire AWG26AWG
Minimum Bend Radius57mm
Max. Power Consumption0.1W Per End
Jacket MaterialPET
Commercial Temperature Range0 to 70°C (32 to 158°F)
Modulation Format8x 50Gbps PAM4
Application400G Ethernet
ProtocolsIEEE 802.3cd, QSFP-DD MSA, CMIS 4.0

Signal and Lane Configuration

The listed modulation format is 8x 50Gbps PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Position Within the Length Range

QDD-400-CU3M is the longest of 6 verified length options in this family. Compared with QDD-400-CU2.5M at 2.5m (8ft), it provides 0.5m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.

Interoperability and Configuration Checks

Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the listed conductor specification is 26AWG; the minimum bend radius is 57mm; the stated power consumption is 0.1W Per End; the jacket material is PET.

Power and Thermal Planning

The rated power consumption is 0.1W Per End. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 26AWG conductors, PET jacket, minimum bend radius 57mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is 400G Ethernet. Listed interface and protocol references include IEEE 802.3cd, QSFP-DD MSA, CMIS 4.0. Confirm that the host firmware and port configuration support the same operating mode.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

At 3m (10ft), this assembly can bridge non-aligned ports or adjacent racks while remaining a single direct-attach link. Support longer horizontal runs with suitable cable management and preserve space for cooling and future maintenance.

Ordering Information

Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. Quantity and any labeling instructions should be attached specifically to QDD-400-CU3M.

Cisco Compatibility and Factory Testing

The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.

Quality Assurance and Packaging

Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Neutral packaging and customer-specific packing documentation are available on request.

Frequently Asked Questions

Is this an original Cisco cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies Cisco QDD-400-CU3M.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.

What details assist a compatibility review?

Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.

How should an unused assembly be stored?

Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.


About us

China Factory:No 168 Golden Ground Industrial Area;
Philippines Address:Makati City,Metro Manila, Philippines

Products catalogues

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

Customer Support

For customer support, please email sales@huihongfiber.com; our support team will get back to you as soon as possible.