Cisco QDD-4ZQ100-CU0.5M Compatible 400G QSFP-DD 8 x 50G PAM4 to 4 x 100G QSFP56 2 x 50G PAM4 Passive Copper Breakout Cable, 0.5m (2ft)

Cisco QDD-4ZQ100-CU0.5M Compatible 400G QSFP-DD 8 x 50G PAM4 to 4 x 100G QSFP56 2 x 50G PAM4 Passive Copper Breakout Cable, 0.5m (2ft)

A successful 400G link depends on host acceptance as well as physical fit. This QDD-4ZQ100-CU0.5M compatible DAC assembly combines QSFP-DD to 4x QSFP56 with a fixed 0.5m (2ft) cable for Cisco equipment. The specifications, configuration guidance and live-link factory verification below describe the exact product supplied under this reference.

OEM Part Number: QDD-4ZQ100-CU0.5MHT Part Number: QDD-4ZQ100-CU0.5M

Product Highlights

  • Compatible alternative to Cisco QDD-4ZQ100-CU0.5M
  • 400G connectivity at 400Gbps
  • Interface configuration: QSFP-DD to 4x QSFP56
  • Fixed length and part number: 0.5m (2ft), QDD-4ZQ100-CU0.5M
  • Conductor specification: 30AWG
  • Maximum power consumption: 0.1W (QSFP-DD End)0.1W (QSFP56 Per End)
  • Minimum bend radius: 35mm
  • Operating temperature: 0 to 70°C (32 to 158°F)

Specifications

HT Part NumberQDD-4ZQ100-CU0.5M
Cisco CompatibleQDD-4ZQ100-CU0.5M
ManufacturerHT
Form FactorQSFP-DD to 4x QSFP56
Max. Data Rate400Gbps
Minimum Bend Radius35mm
Wire AWG30AWG
Cable Length0.5m (2ft)
Jacket MaterialPVC
MediaCopper
Modulation FormatQSFP-DD-8x 50G-PAM4QSFP56-2x 50G-PAM4
Commercial Temperature Range0 to 70°C (32 to 158°F)
Power Supply3.3V
ProtocolsSFF-8665, QSFP-DD MSA, IEEE802.3bj, IEEE802.3 cd
Max. Power Consumption0.1W (QSFP-DD End)0.1W (QSFP56 Per End)
Application400G Ethernet

Signal and Lane Configuration

The listed modulation format is QSFP-DD-8x 50G-PAM4QSFP56-2x 50G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Length Selection and Installation Planning

The 0.5m (2ft) length is suited to closely aligned ports where excessive slack would obstruct airflow or complicate dressing. Measure the actual port-to-port path before choosing QDD-4ZQ100-CU0.5M; even a short assembly must retain the specified bend radius and should never be pulled tight behind the equipment.

Position Within the Length Range

QDD-4ZQ100-CU0.5M is the shortest of 6 verified length options in this family. It is the preferred choice when the port positions are close and cable slack must be kept to a minimum. The next option is QDD-4ZQ100-CU1M at 1m (3ft), adding 0.5m for a less direct routing path; selecting it unnecessarily would leave more cable to dress.

Interoperability and Configuration Checks

Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 35mm; the stated power consumption is 0.1W (QSFP-DD End)0.1W (QSFP56 Per End); the jacket material is PVC.

Power and Thermal Planning

The rated power consumption is 0.1W (QSFP-DD End)0.1W (QSFP56 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 30AWG conductors, PVC jacket, minimum bend radius 35mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is 400G Ethernet. Listed interface and protocol references include SFF-8665, QSFP-DD MSA, IEEE802.3bj, IEEE802.3 cd. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The QSFP-DD to 4x QSFP56 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Ordering Information

Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. Quantity and any labeling instructions should be attached specifically to QDD-4ZQ100-CU0.5M.

Cisco Compatibility and Factory Testing

The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. Where supported by the host, link stability and diagnostic indications are reviewed together with the established link.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.

Quality Assurance and Packaging

Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Volume orders can include customer references on the labels and carton list.

Frequently Asked Questions

Is this an original Cisco cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies Cisco QDD-4ZQ100-CU0.5M.

Does this order code cover multiple lengths?

No. QDD-4ZQ100-CU0.5M refers here to 0.5m (2ft). Every other verified length has a separate part number and page in the length list.

Are separate transceivers or patch leads required?

No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.

Can excess cable be folded into a compact bundle?

No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.


About us

China Factory:No 168 Golden Ground Industrial Area;
Philippines Address:Makati City,Metro Manila, Philippines

Products catalogues

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

Customer Support

For customer support, please email sales@huihongfiber.com; our support team will get back to you as soon as possible.