Cisco QDD-4ZQ100-CU2M Compatible 400G QSFP-DD 8 x 50G PAM4 to 4 x 100G QSFP56 2 x 50G PAM4 Passive Copper Breakout Cable, 2m (7ft)

Cisco QDD-4ZQ100-CU2M Compatible 400G QSFP-DD 8 x 50G PAM4 to 4 x 100G QSFP56 2 x 50G PAM4 Passive Copper Breakout Cable, 2m (7ft)

Use this 2m (7ft) DAC cable for hosts expecting Cisco QDD-4ZQ100-CU2M and a 400G direct-attached interface. The assembly uses QSFP-DD to 4x QSFP56; lane, protocol and breakout considerations are documented alongside the verified table. Every alternative length remains a separate order code with its own technical page.

OEM Part Number: QDD-4ZQ100-CU2MHT Part Number: QDD-4ZQ100-CU2M

Product Highlights

  • Compatible alternative to Cisco QDD-4ZQ100-CU2M
  • 400G connectivity at 400Gbps
  • Interface configuration: QSFP-DD to 4x QSFP56
  • Fixed length and part number: 2m (7ft), QDD-4ZQ100-CU2M
  • Conductor specification: 28AWG
  • Maximum power consumption: 0.1W (QSFP-DD End)0.1W (QSFP56 Per End)
  • Minimum bend radius: 41mm
  • Operating temperature: 0 to 70°C (32 to 158°F)

Specifications

HT Part NumberQDD-4ZQ100-CU2M
Cisco CompatibleQDD-4ZQ100-CU2M
ManufacturerHT
Form FactorQSFP-DD to 4x QSFP56
Max. Data Rate400Gbps
Minimum Bend Radius41mm
Wire AWG28AWG
Cable Length2m (7ft)
Jacket MaterialPVC
MediaCopper
Modulation FormatQSFP-DD-8x 50G-PAM4QSFP56-2x 50G-PAM4
Commercial Temperature Range0 to 70°C (32 to 158°F)
Power Supply3.3V
ProtocolsSFF-8665, QSFP-DD MSA, IEEE802.3bj, IEEE802.3 cd
Max. Power Consumption0.1W (QSFP-DD End)0.1W (QSFP56 Per End)
Application400G Ethernet

Signal and Lane Configuration

The listed modulation format is QSFP-DD-8x 50G-PAM4QSFP56-2x 50G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Network and Protocol Considerations

The intended application is 400G Ethernet. Listed interface and protocol references include SFF-8665, QSFP-DD MSA, IEEE802.3bj, IEEE802.3 cd. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The QSFP-DD to 4x QSFP56 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

QDD-4ZQ100-CU2M provides 2m (7ft) for connections between separated rack units or nearby equipment positions. Plan the route around cable managers and power cords, keeping the assembly free from connector strain while avoiding a large obstruction in the airflow path.

Position Within the Length Range

QDD-4ZQ100-CU2M occupies the middle of this family between QDD-4ZQ100-CU1.5M at 1.5m (5ft) and QDD-4ZQ100-CU2.5M at 2.5m (8ft). It adds 0.5m over the shorter option for extra routing clearance, while the next longer version adds another 0.5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Interoperability and Configuration Checks

Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the listed conductor specification is 28AWG; the minimum bend radius is 41mm; the stated power consumption is 0.1W (QSFP-DD End)0.1W (QSFP56 Per End); the jacket material is PVC.

Power and Thermal Planning

The rated power consumption is 0.1W (QSFP-DD End)0.1W (QSFP56 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 28AWG conductors, PVC jacket, minimum bend radius 41mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Ordering Information

Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. Keep QDD-4ZQ100-CU2M associated with 2m (7ft) throughout the order and receiving record.

Cisco Compatibility and Factory Testing

The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.

Shipping and Lead Time

Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.

Quality Assurance and Packaging

Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Standard protective packing is used by default, with project documentation arranged when requested.

Frequently Asked Questions

Is this an original Cisco cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies Cisco QDD-4ZQ100-CU2M.

How should an unused assembly be stored?

Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.

Can different brands be connected with the same assembly?

Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.

Does this order code cover multiple lengths?

No. QDD-4ZQ100-CU2M refers here to 2m (7ft). Every other verified length has a separate part number and page in the length list.


About us

China Factory:No 168 Golden Ground Industrial Area;
Philippines Address:Makati City,Metro Manila, Philippines

Products catalogues

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

Customer Support

For customer support, please email sales@huihongfiber.com; our support team will get back to you as soon as possible.