QSFP-DD to 4x QSFP28-200G-DAC-2M7FT 200G QSFP-DD 8 x 25G NRZ to 4 x 50G QSFP28 2 x 25G NRZ Passive Copper Breakout Cable, 2m (7ft)

QSFP-DD to 4x QSFP28-200G-DAC-2M7FT 200G QSFP-DD 8 x 25G NRZ to 4 x 50G QSFP28 2 x 25G NRZ Passive Copper Breakout Cable, 2m (7ft)

A successful 200G link depends on host acceptance as well as physical fit. This QSFP-DD to 4x QSFP28-200G-DAC-2M7FT compatible DAC assembly combines QSFP-DD to 4x QSFP28 with a fixed 2m (7ft) cable for Generic equipment. The specifications, configuration guidance and live-link factory verification below describe the exact product supplied under this reference.

OEM Part Number: QSFP-DD to 4x QSFP28-200G-DAC-2M7FTHT Part Number: QSFP-DD to 4x QSFP28-200G-DAC-2M7FT

Product Highlights

  • HT-manufactured DAC assembly in 2m (7ft)
  • 200G connectivity at 200G
  • Interface configuration: QSFP-DD to 4x QSFP28
  • Fixed length and part number: 2m (7ft), QSFP-DD to 4x QSFP28-200G-DAC-2M7FT
  • Conductor specification: 28 AWG
  • Minimum bend radius: 10mm
  • Operating temperature: 0 to 70°C (32 to 158°F)

Specifications

HT Part NumberQSFP-DD to 4x QSFP28-200G-DAC-2M7FT
ManufacturerHT
Connector TypeQSFP-DD to 4x QSFP28
Max Data Rate200G
Minimum Bend Radius10mm
Wire AWG28 AWG
Cable Length3m (10ft)
Jacket MaterialPVC
Operating Temperature0 to 70°C (32 to 158°F)
Storage Temperature-40°C to 85°C (-40°F to 185°F)
Modulation FormatNRZ
ProtocolsQSFP-DD MSA Rev. 5.0, CMIS Rev 4.0, IEEE 802.3cd

Signal and Lane Configuration

The listed modulation format is NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Breakout Port Mapping

The QSFP-DD to 4x QSFP28 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

QSFP-DD to 4x QSFP28-200G-DAC-2M7FT provides 2m (7ft) for connections between separated rack units or nearby equipment positions. Plan the route around cable managers and power cords, keeping the assembly free from connector strain while avoiding a large obstruction in the airflow path.

Position Within the Length Range

QSFP-DD to 4x QSFP28-200G-DAC-2M7FT occupies the middle of this family between QSFP-DD to 4x QSFP28-200G-DAC-1.5M5FT at 1.5m (5ft) and QSFP-DD to 4x QSFP28-200G-DAC-2.5M8FT at 2.5m (8ft). It adds 0.5m over the shorter option for extra routing clearance, while the next longer version adds another 0.5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Interoperability and Configuration Checks

Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the listed conductor specification is 28 AWG; the minimum bend radius is 10mm; the jacket material is PVC.

Cable Construction and Routing

This assembly uses 28 AWG conductors, PVC jacket, minimum bend radius 10mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include QSFP-DD MSA Rev. 5.0, CMIS Rev 4.0, IEEE 802.3cd. Confirm that the host firmware and port configuration support the same operating mode.

Ordering Information

Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. This page’s fixed configuration is 2m (7ft); another length must be quoted under its corresponding part number.

Generic Compatibility and Factory Testing

The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. Where supported by the host, link stability and diagnostic indications are reviewed together with the established link.

Shipping and Lead Time

Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.

Quality Assurance and Packaging

Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Standard protective packing is used by default, with project documentation arranged when requested.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.

What details assist a compatibility review?

Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.

How should an unused assembly be stored?

Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.


About us