Philippines Fiber Optics

Connect the people, connect the world ...

Fiber Optic Cables

QSFP-DD to 4x QSFP28-200G-DAC-3M10FT 200G QSFP-DD 8 x 25G NRZ to 4 x 50G QSFP28 2 x 25G NRZ Passive Copper Breakout Cable, 3m (10ft)

QSFP-DD to 4x QSFP28-200G-DAC-3M10FT 200G QSFP-DD 8 x 25G NRZ to 4 x 50G QSFP28 2 x 25G NRZ Passive Copper Breakout Cable, 3m (10ft)

The QSFP-DD to 4x QSFP28-200G-DAC-3M10FT compatible assembly addresses a specific interoperability requirement: Generic host identification on a 200G DAC link measuring 3m (10ft). Its interface configuration is QSFP-DD to 4x QSFP28. This page explains the physical product, port-configuration checks and related part numbers so selection does not rely on connector appearance alone.

OEM Part Number: QSFP-DD to 4x QSFP28-200G-DAC-3M10FTHT Part Number: QSFP-DD to 4x QSFP28-200G-DAC-3M10FT

Product Highlights

  • HT-manufactured DAC assembly in 3m (10ft)
  • 200G connectivity at 200G
  • Interface configuration: QSFP-DD to 4x QSFP28
  • Fixed length and part number: 3m (10ft), QSFP-DD to 4x QSFP28-200G-DAC-3M10FT
  • Conductor specification: 28 AWG
  • Minimum bend radius: 10mm
  • Operating temperature: 0 to 70°C (32 to 158°F)

Specifications

HT Part NumberQSFP-DD to 4x QSFP28-200G-DAC-3M10FT
ManufacturerHT
Connector TypeQSFP-DD to 4x QSFP28
Max Data Rate200G
Minimum Bend Radius10mm
Wire AWG28 AWG
Cable Length3m (10ft)
Jacket MaterialPVC
Operating Temperature0 to 70°C (32 to 158°F)
Storage Temperature-40°C to 85°C (-40°F to 185°F)
Modulation FormatNRZ
ProtocolsQSFP-DD MSA Rev. 5.0, CMIS Rev 4.0, IEEE 802.3cd

Signal and Lane Configuration

The listed modulation format is NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include QSFP-DD MSA Rev. 5.0, CMIS Rev 4.0, IEEE 802.3cd. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The QSFP-DD to 4x QSFP28 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

At 3m (10ft), this assembly can bridge non-aligned ports or adjacent racks while remaining a single direct-attach link. Support longer horizontal runs with suitable cable management and preserve space for cooling and future maintenance.

Position Within the Length Range

QSFP-DD to 4x QSFP28-200G-DAC-3M10FT is the longest of 6 verified length options in this family. Compared with QSFP-DD to 4x QSFP28-200G-DAC-2.5M8FT at 2.5m (8ft), it provides 0.5m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.

Interoperability and Configuration Checks

Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the listed conductor specification is 28 AWG; the minimum bend radius is 10mm; the jacket material is PVC.

Cable Construction and Routing

This assembly uses 28 AWG conductors, PVC jacket, minimum bend radius 10mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Ordering Information

Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. Keep QSFP-DD to 4x QSFP28-200G-DAC-3M10FT associated with 3m (10ft) throughout the order and receiving record.

Generic Compatibility and Factory Testing

The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. Where supported by the host, link stability and diagnostic indications are reviewed together with the established link.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.

Quality Assurance and Packaging

Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Neutral packaging and customer-specific packing documentation are available on request.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.

What details assist a compatibility review?

Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.

How should an unused assembly be stored?

Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.


About us

China Factory:No 168 Golden Ground Industrial Area;
Philippines Address:Makati City,Metro Manila, Philippines

Products catalogues

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

Customer Support

For customer support, please email sales@huihongfiber.com; our support team will get back to you as soon as possible.