A successful 800G link depends on host acceptance as well as physical fit. This QSFP-DD to QSFP-DD-800G-AEC-1M3FT compatible AEC assembly combines QSFP-DD to QSFP-DD with a fixed 1m (3ft) cable for Generic equipment. The specifications, configuration guidance and live-link factory verification below describe the exact product supplied under this reference.
OEM Part Number: QSFP-DD to QSFP-DD-800G-AEC-1M3FTHT Part Number: QSFP-DD to QSFP-DD-800G-AEC-1M3FT
| HT Part Number | QSFP-DD to QSFP-DD-800G-AEC-1M3FT |
|---|---|
| Manufacturer | HT |
| Form Factor | QSFP-DD to QSFP-DD |
| Max. Data Rate | 800Gbps |
| Media | Copper |
| Cable Type | Active DAC (AEC) |
| Cable Length | 1m (3ft) |
| Jacket Material | PET |
| Minimum Bend Radius | 36.5 |
| Wire AWG | 32AWG |
| Max. Power Consumption | 12W Per End |
| Modulation Format | 8x100G-PAM4 |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Application | 800G Ethernet |
| Protocols | CMIS 5.0, IEEE 802.3ck, QSFP-DD MSA Rev6.3 |
The listed modulation format is 8x100G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
The intended application is 800G Ethernet. Listed interface and protocol references include CMIS 5.0, IEEE 802.3ck, QSFP-DD MSA Rev6.3. Confirm that the host firmware and port configuration support the same operating mode.
At 1m (3ft), QSFP-DD to QSFP-DD-800G-AEC-1M3FT is a practical choice for direct connections within one rack. Route the cable along the intended management path rather than pulling it diagonally across adjacent connectors, and leave enough clearance for insertion, removal and front-panel airflow.
QSFP-DD to QSFP-DD-800G-AEC-1M3FT is the shortest of 4 verified length options in this family. It is the preferred choice when the port positions are close and cable slack must be kept to a minimum. The next option is QSFP-DD to QSFP-DD-800G-AEC-2M7FT at 2m (7ft), adding 1m for a less direct routing path; selecting it unnecessarily would leave more cable to dress.
Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the listed conductor specification is 32AWG; the minimum bend radius is 36.5; the stated power consumption is 12W Per End; the jacket material is PET.
The rated power consumption is 12W Per End. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
This assembly uses 32AWG conductors, PET jacket, minimum bend radius 36.5. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. Quantity and any labeling instructions should be attached specifically to QSFP-DD to QSFP-DD-800G-AEC-1M3FT.
The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.
Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Standard protective packing is used by default, with project documentation arranged when requested.
No. It is manufactured by HT under our own manufacturer identity.
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.
Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.