
The QSFP-DD to QSFP-DD-800G-AEC-5M16FT compatible assembly addresses a specific interoperability requirement: Generic host identification on a 800G AEC link measuring 5m (16ft). Its interface configuration is QSFP-DD to QSFP-DD. This page explains the physical product, port-configuration checks and related part numbers so selection does not rely on connector appearance alone.
OEM Part Number: QSFP-DD to QSFP-DD-800G-AEC-5M16FTHT Part Number: QSFP-DD to QSFP-DD-800G-AEC-5M16FT
| HT Part Number | QSFP-DD to QSFP-DD-800G-AEC-5M16FT |
|---|---|
| Manufacturer | HT |
| Form Factor | QSFP-DD to QSFP-DD |
| Max. Data Rate | 800Gbps |
| Media | Copper |
| Cable Type | Active DAC (AEC) |
| Cable Length | 5m (16ft) |
| Jacket Material | PET |
| Minimum Bend Radius | 36.5 |
| Wire AWG | 32AWG |
| Max. Power Consumption | 12W Per End |
| Modulation Format | 8x100G-PAM4 |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Application | 800G Ethernet |
| Protocols | CMIS 5.0, IEEE 802.3ck, QSFP-DD MSA Rev6.3 |
The listed modulation format is 8x100G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
The rated power consumption is 12W Per End. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
This assembly uses 32AWG conductors, PET jacket, minimum bend radius 36.5. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is 800G Ethernet. Listed interface and protocol references include CMIS 5.0, IEEE 802.3ck, QSFP-DD MSA Rev6.3. Confirm that the host firmware and port configuration support the same operating mode.
The 5m (16ft) length gives QSFP-DD to QSFP-DD-800G-AEC-5M16FT more freedom for adjacent-rack and row-end deployments. Longer copper runs need particular attention to routing weight and bend control; the AEC specification and host support must still match the intended link.
QSFP-DD to QSFP-DD-800G-AEC-5M16FT is the longest of 4 verified length options in this family. Compared with QSFP-DD to QSFP-DD-800G-AEC-3M10FT at 3m (10ft), it provides 2m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.
Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the listed conductor specification is 32AWG; the minimum bend radius is 36.5; the stated power consumption is 12W Per End; the jacket material is PET.
Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. This page’s fixed configuration is 5m (16ft); another length must be quoted under its corresponding part number.
The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. Both connectors are examined before the operating test, which includes link stability and diagnostic indications.
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.
Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Standard protective packing is used by default, with project documentation arranged when requested.
No. It is manufactured by HT under our own manufacturer identity.
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.