A successful 40G link depends on host acceptance as well as physical fit. This QSFP+ to 4 SFP+-40G-AOC-10M33FT compatible AOC assembly combines QSFP+ to 4 SFP+ with a fixed 10m (33ft) cable for Generic equipment. The specifications, configuration guidance and live-link factory verification below describe the exact product supplied under this reference.
OEM Part Number: QSFP+ to 4 SFP+-40G-AOC-10M33FTHT Part Number: QSFP+ to 4 SFP+-40G-AOC-10M33FT
| HT Part Number | QSFP+ to 4 SFP+-40G-AOC-10M33FT |
|---|---|
| Manufacturer | HT |
| Connector Type | QSFP+ to 4 SFP+ |
| Data Rate | 40Gbps |
| Minimum Bend Radius | 30mm |
| Cable Length | 10m (32.81ft) |
| Jacket Material | OFNP |
| Temperature | 0 to 70°C (32 to 158°F) |
| Protocols | 10G/40Gigabit Ethernet or Fibre Channel |
This assembly uses OFNP jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
QSFP+ to 4 SFP+-40G-AOC-10M33FT occupies the middle of this family between QSFP+ to 4 SFP+-40G-AOC-7M23FT at 7m (23ft) and QSFP+ to 4 SFP+-40G-AOC-15M49FT at 15m (49ft). It adds 3m over the shorter option for extra routing clearance, while the next longer version adds another 5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the minimum bend radius is 30mm; the jacket material is OFNP.
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include 10G/40Gigabit Ethernet or Fibre Channel. Confirm that the host firmware and port configuration support the same operating mode.
The QSFP+ to 4 SFP+ configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.
Measure twice before deploying this 10m (33ft) cable: once along the planned route and again after accounting for service access. The objective is adequate reach without a concealed surplus. Support the integrated optical cable and both optical engines, preserve front-panel clearance and check that nearby power cords or sharp hardware cannot damage the jacket. Within this family, QSFP+ to 4 SFP+-40G-AOC-7M23FT is shorter at 7m (23ft), while QSFP+ to 4 SFP+-40G-AOC-15M49FT is the next longer choice at 15m (49ft); comparing those two boundaries helps avoid both tension and unnecessary slack.
Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. Keep QSFP+ to 4 SFP+-40G-AOC-10M33FT associated with 10m (33ft) throughout the order and receiving record.
The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. The check includes receive activity and diagnostic indications, followed by a final inspection of both ends.
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.
Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Volume orders can include customer references on the labels and carton list.
No. It is manufactured by HT under our own manufacturer identity.
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.
Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.
Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.