
Use this 2.5m (8ft) DAC cable for hosts expecting Generic QSFP56 to 2x QSFP56-200G-DAC-2.5M8FT and a 200G direct-attached interface. The assembly uses QSFP56 to 2x QSFP56; lane, protocol and breakout considerations are documented alongside the verified table. Every alternative length remains a separate order code with its own technical page.
OEM Part Number: QSFP56 to 2x QSFP56-200G-DAC-2.5M8FTHT Part Number: QSFP56 to 2x QSFP56-200G-DAC-2.5M8FT
| HT Part Number | QSFP56 to 2x QSFP56-200G-DAC-2.5M8FT |
|---|---|
| Manufacturer | HT |
| Form Factor | QSFP56 to 2x QSFP56 |
| Max. Data Rate | 200Gbps |
| Media | Copper |
| Cable Type | Passive Twinax |
| Cable Length | 2.5m (8ft) |
| Wire AWG | 26AWG |
| Minimum Bend Radius | 30mm |
| Max. Power Consumption | 0.1W (200G End) 0.1W (100G Per End) |
| Jacket Material | PVC (OFNR) |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Protocols | IEEE 802.3cd, SFF-8665, QSFP56 MSA |
The rated power consumption is 0.1W (200G End) 0.1W (100G Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
The 2.5m (8ft) version is useful when a two-metre run would leave insufficient working slack. Before installation, check the complete horizontal and vertical path so that QSFP56 to 2x QSFP56-200G-DAC-2.5M8FT reaches both ports without tension at either connector.
QSFP56 to 2x QSFP56-200G-DAC-2.5M8FT occupies the middle of this family between QSFP56 to 2x QSFP56-200G-DAC-2M7FT at 2m (7ft) and QSFP56 to 2x QSFP56-200G-DAC-3M10FT at 3m (10ft). It adds 0.5m over the shorter option for extra routing clearance, while the next longer version adds another 0.5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the listed conductor specification is 26AWG; the minimum bend radius is 30mm; the stated power consumption is 0.1W (200G End) 0.1W (100G Per End); the jacket material is PVC (OFNR).
This assembly uses 26AWG conductors, PVC (OFNR) jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include IEEE 802.3cd, SFF-8665, QSFP56 MSA. Confirm that the host firmware and port configuration support the same operating mode.
The QSFP56 to 2x QSFP56 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.
Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. Keep QSFP56 to 2x QSFP56-200G-DAC-2.5M8FT associated with 2.5m (8ft) throughout the order and receiving record.
The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. Both connectors are examined before the operating test, which includes link stability and diagnostic indications.
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.
Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Volume orders can include customer references on the labels and carton list.
No. It is manufactured by HT under our own manufacturer identity.
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.