Philippines Fiber Optics

Connect the people, connect the world ...

Fiber Optic Cables

QSFP56 to 2x QSFP56-200G-DAC-2M7FT 200G QSFP56 4 x 50G PAM4 to 2 x 100G QSFP56 2 x 50G PAM4 Passive Copper Breakout Cable, 2m (7ft)

QSFP56 to 2x QSFP56-200G-DAC-2M7FT 200G QSFP56 4 x 50G PAM4 to 2 x 100G QSFP56 2 x 50G PAM4 Passive Copper Breakout Cable, 2m (7ft)

Use this 2m (7ft) DAC cable for hosts expecting Generic QSFP56 to 2x QSFP56-200G-DAC-2M7FT and a 200G direct-attached interface. The assembly uses QSFP56 to 2x QSFP56; lane, protocol and breakout considerations are documented alongside the verified table. Every alternative length remains a separate order code with its own technical page.

OEM Part Number: QSFP56 to 2x QSFP56-200G-DAC-2M7FTHT Part Number: QSFP56 to 2x QSFP56-200G-DAC-2M7FT

Product Highlights

  • HT-manufactured DAC assembly in 2m (7ft)
  • 200G connectivity at 200Gbps
  • Interface configuration: QSFP56 to 2x QSFP56
  • Fixed length and part number: 2m (7ft), QSFP56 to 2x QSFP56-200G-DAC-2M7FT
  • Cable construction: Passive Twinax
  • Conductor specification: 26AWG
  • Maximum power consumption: 0.1W (200G End) 0.1W (100G Per End)
  • Minimum bend radius: 30mm

Specifications

HT Part NumberQSFP56 to 2x QSFP56-200G-DAC-2M7FT
ManufacturerHT
Form FactorQSFP56 to 2x QSFP56
Max. Data Rate200Gbps
MediaCopper
Cable TypePassive Twinax
Cable Length2m (7ft)
Wire AWG26AWG
Minimum Bend Radius30mm
Max. Power Consumption0.1W (200G End) 0.1W (100G Per End)
Jacket MaterialPVC (OFNR)
Commercial Temperature Range0 to 70°C (32 to 158°F)
ProtocolsIEEE 802.3cd, SFF-8665, QSFP56 MSA

Power and Thermal Planning

The rated power consumption is 0.1W (200G End) 0.1W (100G Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 26AWG conductors, PVC (OFNR) jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include IEEE 802.3cd, SFF-8665, QSFP56 MSA. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The QSFP56 to 2x QSFP56 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

QSFP56 to 2x QSFP56-200G-DAC-2M7FT provides 2m (7ft) for connections between separated rack units or nearby equipment positions. Plan the route around cable managers and power cords, keeping the assembly free from connector strain while avoiding a large obstruction in the airflow path.

Position Within the Length Range

QSFP56 to 2x QSFP56-200G-DAC-2M7FT occupies the middle of this family between QSFP56 to 2x QSFP56-200G-DAC-1.5M5FT at 1.5m (5ft) and QSFP56 to 2x QSFP56-200G-DAC-2.5M8FT at 2.5m (8ft). It adds 0.5m over the shorter option for extra routing clearance, while the next longer version adds another 0.5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Interoperability and Configuration Checks

Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the listed conductor specification is 26AWG; the minimum bend radius is 30mm; the stated power consumption is 0.1W (200G End) 0.1W (100G Per End); the jacket material is PVC (OFNR).

Ordering Information

Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. This page’s fixed configuration is 2m (7ft); another length must be quoted under its corresponding part number.

Generic Compatibility and Factory Testing

The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. Both connectors are examined before the operating test, which includes link stability and diagnostic indications.

Shipping and Lead Time

Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.

Quality Assurance and Packaging

Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Volume orders can include customer references on the labels and carton list.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

What details assist a compatibility review?

Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.

How should an unused assembly be stored?

Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.

Can different brands be connected with the same assembly?

Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.


About us

China Factory:No 168 Golden Ground Industrial Area;
Philippines Address:Makati City,Metro Manila, Philippines

Products catalogues

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

Customer Support

For customer support, please email sales@huihongfiber.com; our support team will get back to you as soon as possible.