Use this 5m (16ft) ACC cable for hosts expecting Generic QSFP56 to QSFP56-200G-ACC-5M16FT and a 200G direct-attached interface. The assembly uses QSFP56 to QSFP56; lane, protocol and breakout considerations are documented alongside the verified table. Every alternative length remains a separate order code with its own technical page.
OEM Part Number: QSFP56 to QSFP56-200G-ACC-5M16FTHT Part Number: QSFP56 to QSFP56-200G-ACC-5M16FT
| HT Part Number | QSFP56 to QSFP56-200G-ACC-5M16FT |
|---|---|
| Manufacturer | HT |
| Form Factor | QSFP56 to QSFP56 |
| Max. Data Rate | 200Gbps |
| Media | Copper |
| Cable Type | Active Twinax |
| Cable Length | 5m (16ft) |
| Wire AWG | 28AWG |
| Minimum Bend Radius | 40mm |
| Max. Power Consumption | 1.5W Per End |
| Jacket Material | PVC (OFNR) |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Protocols | IEEE 802.3cd, SFF-8665, SFF-8679, SFF-8636 |
The rated power consumption is 1.5W Per End. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include IEEE 802.3cd, SFF-8665, SFF-8679, SFF-8636. Confirm that the host firmware and port configuration support the same operating mode.
The 5m (16ft) length gives QSFP56 to QSFP56-200G-ACC-5M16FT more freedom for adjacent-rack and row-end deployments. Longer copper runs need particular attention to routing weight and bend control; the ACC specification and host support must still match the intended link.
QSFP56 to QSFP56-200G-ACC-5M16FT occupies the middle of this family between QSFP56 to QSFP56-200G-ACC-4M13FT at 4m (13ft) and QSFP56 to QSFP56-200G-ACC-7M23FT at 7m (23ft). It adds 1m over the shorter option for extra routing clearance, while the next longer version adds another 2m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the listed conductor specification is 28AWG; the minimum bend radius is 40mm; the stated power consumption is 1.5W Per End; the jacket material is PVC (OFNR).
This assembly uses 28AWG conductors, PVC (OFNR) jacket, minimum bend radius 40mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. This page’s fixed configuration is 5m (16ft); another length must be quoted under its corresponding part number.
The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. Both connectors are examined before the operating test, which includes link stability and diagnostic indications.
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.
Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Neutral packaging and customer-specific packing documentation are available on request.
No. It is manufactured by HT under our own manufacturer identity.
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.