Philippines Fiber Optics

Connect the people, connect the world ...

Fiber Optic Cables

QSFP56 to QSFP56-200G-ACC-7M23FT 200G QSFP56 4 x 50G PAM4 Active Copper Twinax Cable, 7m (23ft)

QSFP56 to QSFP56-200G-ACC-7M23FT 200G QSFP56 4 x 50G PAM4 Active Copper Twinax Cable, 7m (23ft)

A successful 200G link depends on host acceptance as well as physical fit. This QSFP56 to QSFP56-200G-ACC-7M23FT compatible ACC assembly combines QSFP56 to QSFP56 with a fixed 7m (23ft) cable for Generic equipment. The specifications, configuration guidance and live-link factory verification below describe the exact product supplied under this reference.

OEM Part Number: QSFP56 to QSFP56-200G-ACC-7M23FTHT Part Number: QSFP56 to QSFP56-200G-ACC-7M23FT

Product Highlights

  • HT-manufactured ACC assembly in 7m (23ft)
  • 200G connectivity at 200Gbps
  • Interface configuration: QSFP56 to QSFP56
  • Fixed length and part number: 7m (23ft), QSFP56 to QSFP56-200G-ACC-7M23FT
  • Cable construction: Active Twinax
  • Conductor specification: 26AWG
  • Maximum power consumption: 1.5W Per End
  • Minimum bend radius: 44.5mm

Specifications

HT Part NumberQSFP56 to QSFP56-200G-ACC-7M23FT
ManufacturerHT
Form FactorQSFP56 to QSFP56
Max. Data Rate200Gbps
MediaCopper
Cable TypeActive Twinax
Cable Length7m (23ft)
Wire AWG26AWG
Minimum Bend Radius44.5mm
Max. Power Consumption1.5W Per End
Jacket MaterialPVC (OFNR)
Commercial Temperature Range0 to 70°C (32 to 158°F)
ProtocolsIEEE 802.3cd, SFF-8665, SFF-8679, SFF-8636

Power and Thermal Planning

The rated power consumption is 1.5W Per End. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 26AWG conductors, PVC (OFNR) jacket, minimum bend radius 44.5mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include IEEE 802.3cd, SFF-8665, SFF-8679, SFF-8636. Confirm that the host firmware and port configuration support the same operating mode.

Length Selection and Installation Planning

Longer assemblies require disciplined cable dressing. For QSFP56 to QSFP56-200G-ACC-7M23FT at 7m (23ft), use the intended managers rather than a diagonal route across the rack, and leave enough space to release each connector. Any service allowance should be loose and supported, with the complete copper assembly and both connector housings protected throughout the path. The next shorter verified assembly is QSFP56 to QSFP56-200G-ACC-5M16FT at 5m (16ft), which is the better comparison when the managed route leaves substantial unused cable.

Position Within the Length Range

QSFP56 to QSFP56-200G-ACC-7M23FT is the longest of 4 verified length options in this family. Compared with QSFP56 to QSFP56-200G-ACC-5M16FT at 5m (16ft), it provides 2m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.

Interoperability and Configuration Checks

Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the listed conductor specification is 26AWG; the minimum bend radius is 44.5mm; the stated power consumption is 1.5W Per End; the jacket material is PVC (OFNR).

Ordering Information

Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. Quantity and any labeling instructions should be attached specifically to QSFP56 to QSFP56-200G-ACC-7M23FT.

Generic Compatibility and Factory Testing

The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. Where supported by the host, link stability and diagnostic indications are reviewed together with the established link.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.

Quality Assurance and Packaging

Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Standard protective packing is used by default, with project documentation arranged when requested.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.

What details assist a compatibility review?

Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.

How should an unused assembly be stored?

Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.


About us

China Factory:No 168 Golden Ground Industrial Area;
Philippines Address:Makati City,Metro Manila, Philippines

Products catalogues

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

Customer Support

For customer support, please email sales@huihongfiber.com; our support team will get back to you as soon as possible.