SFP-DD to 2x SFP56-100G-DAC-1M3FT 100G SFP-DD 2 x 50G PAM4 to 2 x SFP56 50G PAM4 Passive Copper Twinax Cable, 1m (3ft)

SFP-DD to 2x SFP56-100G-DAC-1M3FT 100G SFP-DD 2 x 50G PAM4 to 2 x SFP56 50G PAM4 Passive Copper Twinax Cable, 1m (3ft)

Use this 1m (3ft) DAC cable for hosts expecting Generic SFP-DD to 2x SFP56-100G-DAC-1M3FT and a 100G direct-attached interface. The assembly uses SFP-DD to 2x SFP56; lane, protocol and breakout considerations are documented alongside the verified table. Every alternative length remains a separate order code with its own technical page.

OEM Part Number: SFP-DD to 2x SFP56-100G-DAC-1M3FTHT Part Number: SFP-DD to 2x SFP56-100G-DAC-1M3FT

Product Highlights

  • HT-manufactured DAC assembly in 1m (3ft)
  • 100G connectivity at 100Gbps
  • Interface configuration: SFP-DD to 2x SFP56
  • Fixed length and part number: 1m (3ft), SFP-DD to 2x SFP56-100G-DAC-1M3FT
  • Cable construction: Passive Twinax
  • Conductor specification: 30AWG
  • Maximum power consumption: 0.1W
  • Minimum bend radius: 23.6mm

Specifications

HT Part NumberSFP-DD to 2x SFP56-100G-DAC-1M3FT
ManufacturerHT
Form FactorSFP-DD to 2x SFP56
Max. Data Rate100Gbps
MediaCopper
Cable TypePassive Twinax
Cable Length1m (3ft)
Jacket MaterialPVC (OFNR)
Minimum Bend Radius23.6mm
Wire AWG30AWG
Max. Power Consumption0.1W
Modulation FormatSFP-DD-2x 50G-PAM4SFP56-1x 50G-PAM4
Commercial Temperature Range0 to 70°C (32 to 158°F)
Application100G Ethernet, 128G Fibre Channel
ProtocolsSFPDD: SFP-DD MSA, SFP-DD MIS, IEEE 802.3cdSFP56: SFF-8432, SFF-8402, SFF-8472, IEEE 802.3cd

Signal and Lane Configuration

The listed modulation format is SFP-DD-2x 50G-PAM4SFP56-1x 50G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Cable Construction and Routing

This assembly uses 30AWG conductors, PVC (OFNR) jacket, minimum bend radius 23.6mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is 100G Ethernet, 128G Fibre Channel. Listed interface and protocol references include SFPDD: SFP-DD MSA, SFP-DD MIS, IEEE 802.3cdSFP56: SFF-8432, SFF-8402, SFF-8472, IEEE 802.3cd. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The SFP-DD to 2x SFP56 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

At 1m (3ft), SFP-DD to 2x SFP56-100G-DAC-1M3FT is a practical choice for direct connections within one rack. Route the cable along the intended management path rather than pulling it diagonally across adjacent connectors, and leave enough clearance for insertion, removal and front-panel airflow.

Position Within the Length Range

SFP-DD to 2x SFP56-100G-DAC-1M3FT occupies the middle of this family between SFP-DD to 2x SFP56-100G-DAC-0.5M2FT at 0.5m (2ft) and SFP-DD to 2x SFP56-100G-DAC-2M7FT at 2m (7ft). It adds 0.5m over the shorter option for extra routing clearance, while the next longer version adds another 1m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Interoperability and Configuration Checks

Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 23.6mm; the stated power consumption is 0.1W; the jacket material is PVC (OFNR).

Power and Thermal Planning

The rated power consumption is 0.1W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Ordering Information

Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. This page’s fixed configuration is 1m (3ft); another length must be quoted under its corresponding part number.

Generic Compatibility and Factory Testing

The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. Where supported by the host, link stability and diagnostic indications are reviewed together with the established link.

Shipping and Lead Time

Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.

Quality Assurance and Packaging

Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Standard protective packing is used by default, with project documentation arranged when requested.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Can different brands be connected with the same assembly?

Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.

Does this order code cover multiple lengths?

No. SFP-DD to 2x SFP56-100G-DAC-1M3FT refers here to 1m (3ft). Every other verified length has a separate part number and page in the length list.

Are separate transceivers or patch leads required?

No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.


About us

China Factory:No 168 Golden Ground Industrial Area;
Philippines Address:Makati City,Metro Manila, Philippines

Products catalogues

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

Customer Support

For customer support, please email sales@huihongfiber.com; our support team will get back to you as soon as possible.