
The SFP-DD to 2x SFP56-100G-DAC-3M10FT compatible assembly addresses a specific interoperability requirement: Generic host identification on a 100G DAC link measuring 3m (10ft). Its interface configuration is SFP-DD to 2x SFP56. This page explains the physical product, port-configuration checks and related part numbers so selection does not rely on connector appearance alone.
OEM Part Number: SFP-DD to 2x SFP56-100G-DAC-3M10FTHT Part Number: SFP-DD to 2x SFP56-100G-DAC-3M10FT
| HT Part Number | SFP-DD to 2x SFP56-100G-DAC-3M10FT |
|---|---|
| Manufacturer | HT |
| Form Factor | SFP-DD to 2x SFP56 |
| Max. Data Rate | 100Gbps |
| Media | Copper |
| Cable Type | Passive Twinax |
| Cable Length | 3m (10ft) |
| Jacket Material | PVC (OFNR) |
| Minimum Bend Radius | 28.8mm |
| Wire AWG | 26AWG |
| Max. Power Consumption | 0.1W |
| Modulation Format | SFP-DD-2x 50G-PAM4SFP56-1x 50G-PAM4 |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Application | 100G Ethernet, 128G Fibre Channel |
| Protocols | SFPDD: SFP-DD MSA, SFP-DD MIS, IEEE 802.3cdSFP56: SFF-8432, SFF-8402, SFF-8472, IEEE 802.3cd |
The listed modulation format is SFP-DD-2x 50G-PAM4SFP56-1x 50G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.
At 3m (10ft), this assembly can bridge non-aligned ports or adjacent racks while remaining a single direct-attach link. Support longer horizontal runs with suitable cable management and preserve space for cooling and future maintenance.
SFP-DD to 2x SFP56-100G-DAC-3M10FT is the longest of 4 verified length options in this family. Compared with SFP-DD to 2x SFP56-100G-DAC-2M7FT at 2m (7ft), it provides 1m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.
Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the listed conductor specification is 26AWG; the minimum bend radius is 28.8mm; the stated power consumption is 0.1W; the jacket material is PVC (OFNR).
The rated power consumption is 0.1W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
This assembly uses 26AWG conductors, PVC (OFNR) jacket, minimum bend radius 28.8mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is 100G Ethernet, 128G Fibre Channel. Listed interface and protocol references include SFPDD: SFP-DD MSA, SFP-DD MIS, IEEE 802.3cdSFP56: SFF-8432, SFF-8402, SFF-8472, IEEE 802.3cd. Confirm that the host firmware and port configuration support the same operating mode.
The SFP-DD to 2x SFP56 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. This page’s fixed configuration is 3m (10ft); another length must be quoted under its corresponding part number.
The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. Where supported by the host, link stability and diagnostic indications are reviewed together with the established link.
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.
Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Standard protective packing is used by default, with project documentation arranged when requested.
No. It is manufactured by HT under our own manufacturer identity.
Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.
Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.
No. SFP-DD to 2x SFP56-100G-DAC-3M10FT refers here to 3m (10ft). Every other verified length has a separate part number and page in the length list.