SFP28 to SFP28-25G-ACC-7M23FT 25G SFP28 Active Copper Twinax Cable, 7m (23ft)

SFP28 to SFP28-25G-ACC-7M23FT 25G SFP28 Active Copper Twinax Cable, 7m (23ft)

A successful 25G link depends on host acceptance as well as physical fit. This SFP28 to SFP28-25G-ACC-7M23FT compatible ACC assembly combines SFP28 to SFP28 with a fixed 7m (23ft) cable for Generic equipment. The specifications, configuration guidance and live-link factory verification below describe the exact product supplied under this reference.

OEM Part Number: SFP28 to SFP28-25G-ACC-7M23FTHT Part Number: SFP28 to SFP28-25G-ACC-7M23FT

Product Highlights

  • HT-manufactured ACC assembly in 7m (23ft)
  • 25G connectivity at 25Gbps
  • Interface configuration: SFP28 to SFP28
  • Fixed length and part number: 7m (23ft), SFP28 to SFP28-25G-ACC-7M23FT
  • Cable construction: Active Twinax
  • Conductor specification: 26AWG
  • Maximum power consumption: ≤0.5W
  • Minimum bend radius: 28mm

Specifications

HT Part NumberSFP28 to SFP28-25G-ACC-7M23FT
ManufacturerHT
Form FactorSFP28 to SFP28
Max Data Rate25Gbps
MediaCopper
Cable TypeActive Twinax
Cable Length7m (23ft)
Wire AWG26AWG
Minimum Bend Radius28mm
Power Consumption≤0.5W
Jacket MaterialPVC (OFNR)
Commercial Temperature Range0 to 70°C (32 to 158°F)
ProtocolsIEEE 802.3, SFP28 MSA, SFF-8402

Power and Thermal Planning

The rated power consumption is ≤0.5W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include IEEE 802.3, SFP28 MSA, SFF-8402. Confirm that the host firmware and port configuration support the same operating mode.

Length Selection and Installation Planning

Longer assemblies require disciplined cable dressing. For SFP28 to SFP28-25G-ACC-7M23FT at 7m (23ft), use the intended managers rather than a diagonal route across the rack, and leave enough space to release each connector. Any service allowance should be loose and supported, with the complete copper assembly and both connector housings protected throughout the path. Within this family, SFP28 to SFP28-25G-ACC-6M20FT is shorter at 6m (20ft), while SFP28 to SFP28-25G-ACC-8M26FT is the next longer choice at 8m (26ft); comparing those two boundaries helps avoid both tension and unnecessary slack.

Position Within the Length Range

SFP28 to SFP28-25G-ACC-7M23FT occupies the middle of this family between SFP28 to SFP28-25G-ACC-6M20FT at 6m (20ft) and SFP28 to SFP28-25G-ACC-8M26FT at 8m (26ft). It adds 1m over the shorter option for extra routing clearance, while the next longer version adds another 1m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Interoperability and Configuration Checks

Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the listed conductor specification is 26AWG; the minimum bend radius is 28mm; the stated power consumption is ≤0.5W; the jacket material is PVC (OFNR).

Cable Construction and Routing

This assembly uses 26AWG conductors, PVC (OFNR) jacket, minimum bend radius 28mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Ordering Information

Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. Quantity and any labeling instructions should be attached specifically to SFP28 to SFP28-25G-ACC-7M23FT.

Generic Compatibility and Factory Testing

The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. Both connectors are examined before the operating test, which includes link stability and diagnostic indications.

Shipping and Lead Time

Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.

Quality Assurance and Packaging

Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Volume orders can include customer references on the labels and carton list.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Does this order code cover multiple lengths?

No. SFP28 to SFP28-25G-ACC-7M23FT refers here to 7m (23ft). Every other verified length has a separate part number and page in the length list.

Are separate transceivers or patch leads required?

No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.

Can excess cable be folded into a compact bundle?

No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.


About us

China Factory:No 168 Golden Ground Industrial Area;
Philippines Address:Makati City,Metro Manila, Philippines

Products catalogues

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

Customer Support

For customer support, please email sales@huihongfiber.com; our support team will get back to you as soon as possible.