SFP28 to SFP28-25G-ACC-8M26FT 25G SFP28 Active Copper Twinax Cable, 8m (26ft)

SFP28 to SFP28-25G-ACC-8M26FT 25G SFP28 Active Copper Twinax Cable, 8m (26ft)

The SFP28 to SFP28-25G-ACC-8M26FT compatible assembly addresses a specific interoperability requirement: Generic host identification on a 25G ACC link measuring 8m (26ft). Its interface configuration is SFP28 to SFP28. This page explains the physical product, port-configuration checks and related part numbers so selection does not rely on connector appearance alone.

OEM Part Number: SFP28 to SFP28-25G-ACC-8M26FTHT Part Number: SFP28 to SFP28-25G-ACC-8M26FT

Product Highlights

  • HT-manufactured ACC assembly in 8m (26ft)
  • 25G connectivity at 25Gbps
  • Interface configuration: SFP28 to SFP28
  • Fixed length and part number: 8m (26ft), SFP28 to SFP28-25G-ACC-8M26FT
  • Cable construction: Active Twinax
  • Conductor specification: 26AWG
  • Maximum power consumption: ≤0.5W
  • Minimum bend radius: 28mm

Specifications

HT Part NumberSFP28 to SFP28-25G-ACC-8M26FT
ManufacturerHT
Form FactorSFP28 to SFP28
Max Data Rate25Gbps
MediaCopper
Cable TypeActive Twinax
Cable Length8m (26ft)
Wire AWG26AWG
Minimum Bend Radius28mm
Power Consumption≤0.5W
Jacket MaterialPVC (OFNR)
Commercial Temperature Range0 to 70°C (32 to 158°F)
ProtocolsIEEE 802.3, SFP28 MSA, SFF-8402

Power and Thermal Planning

The rated power consumption is ≤0.5W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Interoperability and Configuration Checks

Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the listed conductor specification is 26AWG; the minimum bend radius is 28mm; the stated power consumption is ≤0.5W; the jacket material is PVC (OFNR).

Cable Construction and Routing

This assembly uses 26AWG conductors, PVC (OFNR) jacket, minimum bend radius 28mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include IEEE 802.3, SFP28 MSA, SFF-8402. Confirm that the host firmware and port configuration support the same operating mode.

Length Selection and Installation Planning

Choose SFP28 to SFP28-25G-ACC-8M26FT when the measured managed path justifies 8m (26ft), not simply to leave a large spare coil. Additional reach can simplify adjacent-rack routing, yet unused cable still needs bend-safe storage and ventilation clearance. Keep identification visible so this extended version is not confused with shorter spares. Within this family, SFP28 to SFP28-25G-ACC-7M23FT is shorter at 7m (23ft), while SFP28 to SFP28-25G-ACC-9M29FT is the next longer choice at 9m (29ft); comparing those two boundaries helps avoid both tension and unnecessary slack.

Position Within the Length Range

SFP28 to SFP28-25G-ACC-8M26FT occupies the middle of this family between SFP28 to SFP28-25G-ACC-7M23FT at 7m (23ft) and SFP28 to SFP28-25G-ACC-9M29FT at 9m (29ft). It adds 1m over the shorter option for extra routing clearance, while the next longer version adds another 1m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Ordering Information

Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. Keep SFP28 to SFP28-25G-ACC-8M26FT associated with 8m (26ft) throughout the order and receiving record.

Generic Compatibility and Factory Testing

The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.

Shipping and Lead Time

Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.

Quality Assurance and Packaging

Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Standard protective packing is used by default, with project documentation arranged when requested.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Can different brands be connected with the same assembly?

Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.

Does this order code cover multiple lengths?

No. SFP28 to SFP28-25G-ACC-8M26FT refers here to 8m (26ft). Every other verified length has a separate part number and page in the length list.

Are separate transceivers or patch leads required?

No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.


About us

China Factory:No 168 Golden Ground Industrial Area;
Philippines Address:Makati City,Metro Manila, Philippines

Products catalogues

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

Customer Support

For customer support, please email sales@huihongfiber.com; our support team will get back to you as soon as possible.