MMC-24 APC to 3 x MTP-8 APC Breakout Cable, 24 Fibers, OM4

MMC-24 APC to 3 x MTP-8 APC Breakout Cable, 24 Fibers, OM4

Projects in the Philippines benefit from keeping the configuration, branch identification and installation requirement consistent across every participating site. The APC-to-APC configuration of the 24FMMCMTPOM4 breakout carries 24 OM4 fibers from one MMC APC female connector to three MTP-8 APC Elite female legs. All joint points use APC polish, and the branch transition follows factory harness polarity. It gives three eight-fiber multimode optical routes in one compact, terminated under factory control item.

Product Highlights

  • MMC Female to MTP® Female, 24 Fibers
  • OM4 50/125μm, bend-insensitive fiber
  • MMC insertion loss ≤0.35dB, return loss ≥40/45dB (MMC/MTP®)
  • Harness Polarity wiring scheme
  • 2.5mm Plenum (OFNP) cable
  • Standard length options: 1m (3ft), 2m (7ft), 3m (10ft)

Specifications

Part Number24FMMCMTPOM4
ManufacturerHT
Connector AUS Conec MMC Female (Non-Pinned)
Connector BUS Conec MTP® Elite Female (Non-Pinned)
Polish TypeAPC to APC
Glass FiberBend Insensitive Fiber
Fiber ModeOM4 50/125μm
Wavelength850/1300nm
Fiber Count24 Fibers
PolarityHarness Polarity
Cable Outside Diameter (OD)2.5mm
Cable JacketPlenum (OFNP)
Min. Bend Radius (Optical Fiber)7.5mm
Min. Bend Radius (Fiber Cable)20/10D (Dynamic/Static)
Tensile Strength (Long Term)30N
Tensile Strength (Short Term)100N
Insertion Loss≤0.35dB
Return Loss≥40/45dB (MMC/MTP®)
Attenuation at 850nm≤2.3dB/km
Attenuation at 1300nm≤0.6dB/km
Operating Temperature-10 to 60°C (14 to 140℉)
Storage Temperature-10 to 70°C (14 to 158℉)

A three-way fan-out with uniform polish

This fiber cable is appropriate when both the MMC infrastructure and all three MTP destinations are suited to APC. The mating connectors are female and non-pinned; as a result, pinned mates are applicable throughout. establish that the application truly calls for three eight-fiber branches and that no additional polarity reversal is introduced by the connected trunk or cassette before implementation.

Loss values for the complete optical path

The factory-built assembly is rated at 0.35dB maximum insertion loss, with at least 40dB return loss at MMC and 45dB at MTP APC. Use these connector-specific values when reviewing the passive optical path. OM4 operation at 850/1300nm supports multimode systems, but allowable distance and total joint count remain properties of the complete transceiver optical path.

Installing and identifying three APC branches

Standard size options are 1m (3ft), 2m (7ft) and 3m (10ft), with non-standard lengths in feet or meters. Because three equivalent MTP connectors leave one fan-out, branch tags are most importantly valuable. Respect gentle routing around the breakout body, review every ferrule and cap any branch that should not be treated as connected immediately.

Ordering and Factory Support

List 24FMMCMTPOM4 in the APC-to-APC three-leg design, with length and unit count. If the three branches terminate in separate rack locations, give the applicable leg arrangement and labeling rather than relying on a standard fan-out layout. Customers in the Philippines can include multi-site labeling or documentation requirements when requesting a project quotation.

 

About us

China Factory:No 168 Golden Ground Industrial Area;
Philippines Address:Makati City,Metro Manila, Philippines

Products catalogues

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

Customer Support

For customer support, please email sales@huihongfiber.com; our support team will get back to you as soon as possible.