Philippines Fiber Optics

Connect the people, connect the world ...

Fiber Optic Cables

Custom MTP-12 Armored Trunk Cable, 12-144 Fibers, OS2

Custom MTP-12 Armored Trunk Cable, 12-144 Fibers, OS2

Projects in the Philippines benefit from keeping the configuration, branch identification and installation requirement consistent across every participating site. This configured-to-order trunk cable builds 12 to 144 OS2 9/125µm G.657.A1 fibers into a double-jacketed armored item terminated with US Conec MTP Elite connectors. It brings the backbone-class 0.35dB maximum insertion loss of elite MTP terminations to routes that need real mechanical protection: between buildings, through industrial plant, or anywhere a trunk must survive the pathway instead of being protected by it.

Product Highlights

  • Double jacket with helical steel armor; OFNP or LSZH
  • Polarity Type A, B or C to the link design
  • 200N long-term, 660N short-term tensile rating
  • 12 to 144 fibers, Base-12 OS2 9/125µm G.657.A1
  • US Conec MTP Elite connectors, female or male, APC
  • Insertion loss ≤0.35dB, 0.15dB typical per MTP mated pair

Specifications

Connector AUS Conec MTP Elite, Female or Male
Connector BUS Conec MTP Elite, Female or Male
Polish TypeAPC to APC
Fiber ModeOS2 9/125µm
Wavelength1310/1550nm
Glass FiberG.657.A1
Fiber Count12-144 Fibers (Base-12)
PolarityType A / Type B / Type C
Cable JacketPlenum (OFNP) / LSZH
Cable StructureDouble Jacket, Armored
Trunk OD4.5-14.2mm (by fiber count)
Breakout OD2.0mm
Breakout Length0.84m
Min. Bend Radius10mm
Insertion Loss≤0.35dB (0.15dB Typ.)
Return Loss≥65dB
Attenuation at 1310nm≤0.35dB/km
Attenuation at 1550nm≤0.21dB/km
Tensile Strength200N long-term / 660N short-term
Operating TemperatureOFNP: -10 to 60°C; LSZH: -10 to 70°C
Storage TemperatureOFNP: -10 to 70°C; LSZH: -20 to 70°C

Armored trunk cabling for backbone links

Backbone trunks cross the most hostile pathways in a facility: riser shafts shared with power, inter-building conduits, plant rooms with moving machinery. The double-jacket armored design puts a helical steel tube around the fiber core; as a result, this backbone cable carries the mechanical rating itself and the channel is not intended to depend on the condition of the conduit.

MTP Elite performance and the loss budget

Parallel-optic links chain numerous mated pairs; as a result, per-connector loss decides whether the optical path closes. MTP Elite ferrules hold insertion loss to 0.35dB maximum with 0.15dB typical, roughly half the allowance of standard MTP terminations, which buys real headroom when the design stacks a trunk, two cassettes and patch patch leads end to end.

Polarity: Type A, Type B and Type C

MTP links must land transmit on receive, and this backbone cable polarity is how that is engineered. Type An is straight-through, Type B is reversed, Type C is pair-flipped; the right alternative is governed by the cassette and duplex cord plan at both cable ends. State the polarity method with the inquiry and this backbone cable is built and labeled to match it.

Fiber counts from 12 to 144

Base-12 design scales the equivalent trunk design from a single 12-fiber tube to 144 fibers in a 14.2mm double-jacketed build. Breakout legs are 2.0mm at 0.84m as standard, with pulling eyes and alternative leg arrangements provided on order for long or difficult pulls.

Pulling and installation practices

Armored trunks pull like a cable, not like a patch cord: respect the 200N long-term limit, use the pulling eye alternative on long or conduit routes, and feed this backbone cable rather than dragging it around bends. The 10mm minimum bend radius of the G.657.A1 core is generous, but the practical limit on site is set by this backbone cable OD; as a result, plan sweeps rather than right-angle turns at every direction change.

Length selection and customization

Trunks are built to the channel: typical orders run from 1m (3ft) equipment-room links to 30m (98ft) and well beyond for inter-building pulls. Give the measured channel with allowance for vertical drops and service loops, and the factory confirms the build and packaging for the stated length.

Production testing and quality assurance

Every MTP termination is interferometry-checked for end-face geometry, and each finished trunk is 100% insertion loss and return loss tested on all fibers, with results shipped against the serial number. The 0.35dB maximum and 65dB return figures are verified per mated pair, and the armor and jacket are inspected over the full trunk length. Project teams in the Philippines can carry this requirement into the site documentation used by each contractor.

Placing an Order and Factory Support

Send the fiber count, connector gender per end, polarity type, jacket rating, channel length and any breakout or pulling-eye criteria. The factory returns a design layout with the quotation, and production starts once the layout is approved. Customers in the Philippines can include multi-site labeling or documentation requirements when requesting a project quotation.

 

About us

China Factory:No 168 Golden Ground Industrial Area;
Philippines Address:Makati City,Metro Manila, Philippines

Products catalogues

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

Customer Support

For customer support, please email sales@huihongfiber.com; our support team will get back to you as soon as possible.