A successful 400G link depends on host acceptance as well as physical fit. This QSFP-DD to 8x 50G SFP56-400G-AOC-10M33FT compatible AOC assembly combines QSFP-DD to 8x 50G SFP56 with a fixed 10m (33ft) cable for Generic equipment. The specifications, configuration guidance and live-link factory verification below describe the exact product supplied under this reference.
OEM Part Number: QSFP-DD to 8x 50G SFP56-400G-AOC-10M33FTHT Part Number: QSFP-DD to 8x 50G SFP56-400G-AOC-10M33FT
| HT Part Number | QSFP-DD to 8x 50G SFP56-400G-AOC-10M33FT |
|---|---|
| Manufacturer | HT |
| Form Factor | QSFP-DD to 8x 50G SFP56 |
| Max. Data Rate | 425Gbps (8x 53.125GGbps) |
| Cable Length | 10m |
| Cable Type | OM3 |
| Minimum Bend Radius | 30mm |
| Max. Power Consumption | 10W (QSFP-DD End) 3W (SFP56 Per End) |
| Transmitter Type | VSCEL |
| Receiver Type | PIN |
| Modulation Format | PAM4 |
| Wavelength | 850nm |
| Jacket Material | OFNP |
| BER | 2.4E-4 |
| Inbuilt FEC | No |
| Operating Temperature Range | 0 to 70°C (32 to 158°F) |
| Protocols | QSFP-DD MSA, SFP56 MSA, IEEE 802.3cd |
The listed modulation format is PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the minimum bend radius is 30mm; the stated power consumption is 10W (QSFP-DD End) 3W (SFP56 Per End); the jacket material is OFNP.
The rated power consumption is 10W (QSFP-DD End) 3W (SFP56 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
This assembly uses OFNP jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include QSFP-DD MSA, SFP56 MSA, IEEE 802.3cd. Confirm that the host firmware and port configuration support the same operating mode.
The QSFP-DD to 8x 50G SFP56 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.
Extended reach changes the installation checks for QSFP-DD to 8x 50G SFP56-400G-AOC-10M33FT. Confirm that 10m (33ft) follows the intended route without tension, then verify that intermediate supports do not squeeze the jacket or hide the connectors behind adjacent cables. Both hosts must still match the stated interface and lane configuration. Within this family, QSFP-DD to 8x 50G SFP56-400G-AOC-7M23FT is shorter at 7m (23ft), while QSFP-DD to 8x 50G SFP56-400G-AOC-15M49FT is the next longer choice at 15m (49ft); comparing those two boundaries helps avoid both tension and unnecessary slack.
QSFP-DD to 8x 50G SFP56-400G-AOC-10M33FT occupies the middle of this family between QSFP-DD to 8x 50G SFP56-400G-AOC-7M23FT at 7m (23ft) and QSFP-DD to 8x 50G SFP56-400G-AOC-15M49FT at 15m (49ft). It adds 3m over the shorter option for extra routing clearance, while the next longer version adds another 5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. Quantity and any labeling instructions should be attached specifically to QSFP-DD to 8x 50G SFP56-400G-AOC-10M33FT.
The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. The check includes receive activity and diagnostic indications, followed by a final inspection of both ends.
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.
Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Standard protective packing is used by default, with project documentation arranged when requested.
No. It is manufactured by HT under our own manufacturer identity.
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.