Use this 15m (49ft) AOC cable for hosts expecting Generic QSFP-DD to 8x 50G SFP56-400G-AOC-15M49FT and a 400G direct-attached interface. The assembly uses QSFP-DD to 8x 50G SFP56; lane, protocol and breakout considerations are documented alongside the verified table. Every alternative length remains a separate order code with its own technical page.
OEM Part Number: QSFP-DD to 8x 50G SFP56-400G-AOC-15M49FTHT Part Number: QSFP-DD to 8x 50G SFP56-400G-AOC-15M49FT
| HT Part Number | QSFP-DD to 8x 50G SFP56-400G-AOC-15M49FT |
|---|---|
| Manufacturer | HT |
| Form Factor | QSFP-DD to 8x 50G SFP56 |
| Max. Data Rate | 425Gbps (8x 53.125GGbps) |
| Cable Length | 15m |
| Cable Type | OM3 |
| Minimum Bend Radius | 30mm |
| Max. Power Consumption | 10W (QSFP-DD End) 3W (SFP56 Per End) |
| Transmitter Type | VSCEL |
| Receiver Type | PIN |
| Modulation Format | PAM4 |
| Wavelength | 850nm |
| Jacket Material | OFNP |
| BER | 2.4E-4 |
| Inbuilt FEC | No |
| Operating Temperature Range | 0 to 70°C (32 to 158°F) |
| Protocols | QSFP-DD MSA, SFP56 MSA, IEEE 802.3cd |
The listed modulation format is PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include QSFP-DD MSA, SFP56 MSA, IEEE 802.3cd. Confirm that the host firmware and port configuration support the same operating mode.
The QSFP-DD to 8x 50G SFP56 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.
For this 15m (49ft) version, prepare the destination pathway before connecting either end. A longer assembly can cross separated equipment positions, but its weight and service slack must remain supported without blocking airflow. Handle the integrated optical cable and both optical engines as one factory-terminated product and never pull a connector into position by the cable. Within this family, QSFP-DD to 8x 50G SFP56-400G-AOC-10M33FT is shorter at 10m (33ft), while QSFP-DD to 8x 50G SFP56-400G-AOC-20M66FT is the next longer choice at 20m (66ft); comparing those two boundaries helps avoid both tension and unnecessary slack.
QSFP-DD to 8x 50G SFP56-400G-AOC-15M49FT occupies the middle of this family between QSFP-DD to 8x 50G SFP56-400G-AOC-10M33FT at 10m (33ft) and QSFP-DD to 8x 50G SFP56-400G-AOC-20M66FT at 20m (66ft). It adds 5m over the shorter option for extra routing clearance, while the next longer version adds another 5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the minimum bend radius is 30mm; the stated power consumption is 10W (QSFP-DD End) 3W (SFP56 Per End); the jacket material is OFNP.
The rated power consumption is 10W (QSFP-DD End) 3W (SFP56 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
This assembly uses OFNP jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. Keep QSFP-DD to 8x 50G SFP56-400G-AOC-15M49FT associated with 15m (49ft) throughout the order and receiving record.
The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. Both connectors are examined before the operating test, which includes receive activity and diagnostic indications.
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.
Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Neutral packaging and customer-specific packing documentation are available on request.
No. It is manufactured by HT under our own manufacturer identity.
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.