Philippines Fiber Optics

Connect the people, connect the world ...

Fiber Optic Cables

QSFP-DD to 8x 50G SFP56-400G-AOC-70M230FT 400G QSFP-DD 8 x 50G PAM4 to 8 x 50G SFP56 25G NRZ Active Optical Breakout Cable, 70m (230ft)

QSFP-DD to 8x 50G SFP56-400G-AOC-70M230FT 400G QSFP-DD 8 x 50G PAM4 to 8 x 50G SFP56 25G NRZ Active Optical Breakout Cable, 70m (230ft)

The QSFP-DD to 8x 50G SFP56-400G-AOC-70M230FT compatible assembly addresses a specific interoperability requirement: Generic host identification on a 400G AOC link measuring 70m (230ft). Its interface configuration is QSFP-DD to 8x 50G SFP56. This page explains the physical product, port-configuration checks and related part numbers so selection does not rely on connector appearance alone.

OEM Part Number: QSFP-DD to 8x 50G SFP56-400G-AOC-70M230FTHT Part Number: QSFP-DD to 8x 50G SFP56-400G-AOC-70M230FT

Product Highlights

  • HT-manufactured AOC assembly in 70m (230ft)
  • 400G connectivity at 425Gbps (8x 53.125GGbps)
  • Interface configuration: QSFP-DD to 8x 50G SFP56
  • Fixed length and part number: 70m (230ft), QSFP-DD to 8x 50G SFP56-400G-AOC-70M230FT
  • Cable construction: OM3
  • Maximum power consumption: 10W (QSFP-DD End) 3W (SFP56 Per End)
  • Minimum bend radius: 30mm

Specifications

HT Part NumberQSFP-DD to 8x 50G SFP56-400G-AOC-70M230FT
ManufacturerHT
Form FactorQSFP-DD to 8x 50G SFP56
Max. Data Rate425Gbps (8x 53.125GGbps)
Cable Length70m
Cable TypeOM3
Minimum Bend Radius30mm
Max. Power Consumption10W (QSFP-DD End) 3W (SFP56 Per End)
Transmitter TypeVSCEL
Receiver TypePIN
Modulation FormatPAM4
Wavelength850nm
Jacket MaterialOFNP
BER2.4E-4
Inbuilt FECNo
Operating Temperature Range0 to 70°C (32 to 158°F)
ProtocolsQSFP-DD MSA, SFP56 MSA, IEEE 802.3cd

Signal and Lane Configuration

The listed modulation format is PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Position Within the Length Range

QSFP-DD to 8x 50G SFP56-400G-AOC-70M230FT is the longest of 12 verified length options in this family. Compared with QSFP-DD to 8x 50G SFP56-400G-AOC-50M164FT at 50m (164ft), it provides 20m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.

Interoperability and Configuration Checks

Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the minimum bend radius is 30mm; the stated power consumption is 10W (QSFP-DD End) 3W (SFP56 Per End); the jacket material is OFNP.

Power and Thermal Planning

The rated power consumption is 10W (QSFP-DD End) 3W (SFP56 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses OFNP jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include QSFP-DD MSA, SFP56 MSA, IEEE 802.3cd. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The QSFP-DD to 8x 50G SFP56 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Integrated Optical Assembly

The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.

Length Selection and Installation Planning

At 70m (230ft), QSFP-DD to 8x 50G SFP56-400G-AOC-70M230FT should be planned as an extended equipment-room connection rather than a short in-rack jumper. Mark the complete vertical and horizontal route before installation, including every manager the cable will actually pass through. Support the integrated optical cable and both optical engines along that path and keep both ends free from pull loads. The next shorter verified assembly is QSFP-DD to 8x 50G SFP56-400G-AOC-50M164FT at 50m (164ft), which is the better comparison when the managed route leaves substantial unused cable.

Ordering Information

Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. This page’s fixed configuration is 70m (230ft); another length must be quoted under its corresponding part number.

Generic Compatibility and Factory Testing

The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. The check includes receive activity and diagnostic indications, followed by a final inspection of both ends.

Shipping and Lead Time

Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.

Quality Assurance and Packaging

Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Volume orders can include customer references on the labels and carton list.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

What details assist a compatibility review?

Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.

How should an unused assembly be stored?

Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.

Can different brands be connected with the same assembly?

Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.


About us

China Factory:No 168 Golden Ground Industrial Area;
Philippines Address:Makati City,Metro Manila, Philippines

Products catalogues

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

Customer Support

For customer support, please email sales@huihongfiber.com; our support team will get back to you as soon as possible.