The QSFP28 to QSFP28-100G-ACC-1M3FT compatible assembly addresses a specific interoperability requirement: Generic host identification on a 100G ACC link measuring 1m (3ft). Its interface configuration is QSFP28 to QSFP28. This page explains the physical product, port-configuration checks and related part numbers so selection does not rely on connector appearance alone.
OEM Part Number: QSFP28 to QSFP28-100G-ACC-1M3FTHT Part Number: QSFP28 to QSFP28-100G-ACC-1M3FT
| HT Part Number | QSFP28 to QSFP28-100G-ACC-1M3FT |
|---|---|
| Manufacturer | HT |
| Connector Type | QSFP28 to QSFP28 |
| Max Data Rate | 100Gbps |
| Media | Copper |
| Power Consumption | ≤1.5W |
| Min. Bend Radius | 27.5mm |
| Wire AWG | 30AWG |
| Cable Length | 1m |
| Jacket Material | PVC (OFNR) |
| Cable Type | Active Twinax |
| Commercial Temperature Range | 0 to 70℃ (32 to 158°F) |
| Modulation Format | 4x 25G-NRZ to Dual 2x 25G-NRZ |
| Application | 100G Ethernet |
| Protocols | SFF-8665, QSFP28 MSA, SFF-8636, SFF-8679 |
The listed modulation format is 4x 25G-NRZ to Dual 2x 25G-NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
At 1m (3ft), QSFP28 to QSFP28-100G-ACC-1M3FT is a practical choice for direct connections within one rack. Route the cable along the intended management path rather than pulling it diagonally across adjacent connectors, and leave enough clearance for insertion, removal and front-panel airflow.
QSFP28 to QSFP28-100G-ACC-1M3FT is the shortest of 6 verified length options in this family. It is the preferred choice when the port positions are close and cable slack must be kept to a minimum. The next option is QSFP28 to QSFP28-100G-ACC-2M7FT at 2m (7ft), adding 1m for a less direct routing path; selecting it unnecessarily would leave more cable to dress.
Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the listed conductor specification is 30AWG; the stated power consumption is ≤1.5W; the jacket material is PVC (OFNR).
The rated power consumption is ≤1.5W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
This assembly uses 30AWG conductors, PVC (OFNR) jacket. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is 100G Ethernet. Listed interface and protocol references include SFF-8665, QSFP28 MSA, SFF-8636, SFF-8679. Confirm that the host firmware and port configuration support the same operating mode.
The QSFP28 to QSFP28 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. This page’s fixed configuration is 1m (3ft); another length must be quoted under its corresponding part number.
The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. Where supported by the host, link stability and diagnostic indications are reviewed together with the established link.
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.
Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Standard protective packing is used by default, with project documentation arranged when requested.
No. It is manufactured by HT under our own manufacturer identity.
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.