A successful 100G link depends on host acceptance as well as physical fit. This QSFP28 to QSFP28-100G-ACC-2M7FT compatible ACC assembly combines QSFP28 to QSFP28 with a fixed 2m (7ft) cable for Generic equipment. The specifications, configuration guidance and live-link factory verification below describe the exact product supplied under this reference.
OEM Part Number: QSFP28 to QSFP28-100G-ACC-2M7FTHT Part Number: QSFP28 to QSFP28-100G-ACC-2M7FT
| HT Part Number | QSFP28 to QSFP28-100G-ACC-2M7FT |
|---|---|
| Manufacturer | HT |
| Connector Type | QSFP28 to QSFP28 |
| Max Data Rate | 100Gbps |
| Media | Copper |
| Power Consumption | ≤1.5W |
| Min. Bend Radius | 27.5mm |
| Wire AWG | 30AWG |
| Cable Length | 2m |
| Jacket Material | PVC (OFNR) |
| Cable Type | Active Twinax |
| Commercial Temperature Range | 0 to 70℃ (32 to 158°F) |
| Modulation Format | 4x 25G-NRZ to Dual 2x 25G-NRZ |
| Application | 100G Ethernet |
| Protocols | SFF-8665, QSFP28 MSA, SFF-8636, SFF-8679 |
The listed modulation format is 4x 25G-NRZ to Dual 2x 25G-NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
QSFP28 to QSFP28-100G-ACC-2M7FT occupies the middle of this family between QSFP28 to QSFP28-100G-ACC-1M3FT at 1m (3ft) and QSFP28 to QSFP28-100G-ACC-3M10FT at 3m (10ft). It adds 1m over the shorter option for extra routing clearance, while the next longer version adds another 1m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the listed conductor specification is 30AWG; the stated power consumption is ≤1.5W; the jacket material is PVC (OFNR).
The rated power consumption is ≤1.5W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
This assembly uses 30AWG conductors, PVC (OFNR) jacket. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is 100G Ethernet. Listed interface and protocol references include SFF-8665, QSFP28 MSA, SFF-8636, SFF-8679. Confirm that the host firmware and port configuration support the same operating mode.
The QSFP28 to QSFP28 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
QSFP28 to QSFP28-100G-ACC-2M7FT provides 2m (7ft) for connections between separated rack units or nearby equipment positions. Plan the route around cable managers and power cords, keeping the assembly free from connector strain while avoiding a large obstruction in the airflow path.
Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. Keep QSFP28 to QSFP28-100G-ACC-2M7FT associated with 2m (7ft) throughout the order and receiving record.
The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. Both connectors are examined before the operating test, which includes link stability and diagnostic indications.
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.
Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Neutral packaging and customer-specific packing documentation are available on request.
No. It is manufactured by HT under our own manufacturer identity.
No. QSFP28 to QSFP28-100G-ACC-2M7FT refers here to 2m (7ft). Every other verified length has a separate part number and page in the length list.
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.