A successful 100G link depends on host acceptance as well as physical fit. This QSFP28 to QSFP28-100G-ACC-7M23FT compatible ACC assembly combines QSFP28 to QSFP28 with a fixed 7m (23ft) cable for Generic equipment. The specifications, configuration guidance and live-link factory verification below describe the exact product supplied under this reference.
OEM Part Number: QSFP28 to QSFP28-100G-ACC-7M23FTHT Part Number: QSFP28 to QSFP28-100G-ACC-7M23FT
| HT Part Number | QSFP28 to QSFP28-100G-ACC-7M23FT |
|---|---|
| Manufacturer | HT |
| Connector Type | QSFP28 to QSFP28 |
| Max Data Rate | 100Gbps |
| Media | Copper |
| Power Consumption | ≤1.5W |
| Min. Bend Radius | 36.5mm |
| Wire AWG | 26AWG |
| Cable Length | 7m |
| Jacket Material | PVC (OFNR) |
| Cable Type | Active Twinax |
| Commercial Temperature Range | 0 to 70℃ (32 to 158°F) |
| Modulation Format | 4x 25G-NRZ to Dual 2x 25G-NRZ |
| Application | 100G Ethernet |
| Protocols | SFF-8665, QSFP28 MSA, SFF-8636, SFF-8679 |
The listed modulation format is 4x 25G-NRZ to Dual 2x 25G-NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
QSFP28 to QSFP28-100G-ACC-7M23FT occupies the middle of this family between QSFP28 to QSFP28-100G-ACC-5M16FT at 5m (16ft) and QSFP28 to QSFP28-100G-ACC-9M29FT at 9m (29ft). It adds 2m over the shorter option for extra routing clearance, while the next longer version adds another 2m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Check three layers before deployment: the host must accept the cable identification, the port must support the stated aggregate rate, and the lane configuration must match the attached interfaces. On breakout hardware, also confirm channelization and the mapping of every branch. These checks are particularly important when similar-looking ports operate at different speeds or under different firmware settings. For this assembly, the listed conductor specification is 26AWG; the stated power consumption is ≤1.5W; the jacket material is PVC (OFNR).
The rated power consumption is ≤1.5W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
This assembly uses 26AWG conductors, PVC (OFNR) jacket. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is 100G Ethernet. Listed interface and protocol references include SFF-8665, QSFP28 MSA, SFF-8636, SFF-8679. Confirm that the host firmware and port configuration support the same operating mode.
The QSFP28 to QSFP28 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
A 7m (23ft) run can remain tidy when its pathway and service allowance are planned together. Keep the complete copper assembly and both connector housings away from tight cable-tie pressure, verify bend control at changes of direction and ensure that neither port supports the assembly’s weight. Record the exact order code after acceptance. Within this family, QSFP28 to QSFP28-100G-ACC-5M16FT is shorter at 5m (16ft), while QSFP28 to QSFP28-100G-ACC-9M29FT is the next longer choice at 9m (29ft); comparing those two boundaries helps avoid both tension and unnecessary slack.
Specify the OEM part number and fixed length, then provide the intended host configuration if the link uses channelized or breakout ports. Separate part numbers should be used for separate lengths. This gives the compatibility review enough information to check both the physical assembly and the intended operating mode. Keep QSFP28 to QSFP28-100G-ACC-7M23FT associated with 7m (23ft) throughout the order and receiving record.
The verification process combines digital identification with a live link test and diagnostic observation. Host model, hardware revision and software release are useful inputs because qualification behavior can change between platform generations; those details allow platform-specific requirements to be reviewed before the cable is packed. Both connectors are examined before the operating test, which includes link stability and diagnostic indications.
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.
Functional inspection covers identification, link establishment and the condition of both connector assemblies. The cable is then protected against dust and connector damage and packed without sharp bends. Labels can include the customer reference and host-platform note when requested for a controlled deployment. Volume orders can include customer references on the labels and carton list.
No. It is manufactured by HT under our own manufacturer identity.
Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.
No. QSFP28 to QSFP28-100G-ACC-7M23FT refers here to 7m (23ft). Every other verified length has a separate part number and page in the length list.
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.