LC UPC Simplex Armored Fiber Patch Cable, OS2, Riser (OFCR)

LC UPC Simplex Armored Fiber Patch Cable, OS2, Riser (OFCR)

Projects in the Philippines benefit from keeping the configuration, branch identification and installation requirement consistent across every participating site. This simplex armored patch cable carries a single OS2 9/125µm fiber between two LC UPC connectors, protected by a helical stainless steel tube beneath the blue 3.0mm riser-rated (OFCR) jacket. It matches the LC interface found on modern BiDi transceivers and space-efficient frames, and adds the steel protection that exposed patching fields and under-floor routes demand.

Product Highlights

  • Riser (OFCR) flame rating for vertical building pathways
  • Insertion loss ≤0.3dB, return loss ≥50dB
  • Stock lengths 1m to 30m; custom lengths and jackets on request
  • LC UPC to LC UPC simplex, OS2 9/125µm single mode
  • Helical stainless steel armor against crush, impact and rodents
  • G.657.A1 bend-insensitive fiber, 10/5D bend radius

Specifications

Connector TypeLC to LC
Polish TypeUPC to UPC
Fiber ModeOS2 9/125µm
Wavelength1310/1550nm
Fiber CountSimplex
Fiber GradeG.657.A1 (Compatible with G.652.D)
Min. Bend Radius (Fiber Cable)10/5D (Dynamic/Static)
Cable Outside Diameter (OD)3.0mm
Flame RatingRiser (OFCR)
Construction TypeSingle Armored, Stainless Steel Tube
Tensile Strength120/225N (Long/Short Term)
Insertion Loss≤0.3dB
Return Loss≥50dB
Operating Temperature-20 to 70°C (-4 to 158°F)
Storage Temperature-40 to 70°C (-40 to 158°F)

LC simplex in high-density frames

The LC interface packs twice the ports into the equivalent panel space as SC, which is why modern BiDi optics and dense frames are almost universally LC. A simplex LC cord patches a single lit strand between those ports without the bulk and slack of a duplex item, keeping space-efficient fields readable and leaving neighboring latches accessible.

Single-fiber BiDi transmission

BiDi SFP, SFP+ and SFP28 modules transmit and receive on separate wavelengths over one strand; as a result, the right cord has exactly one fiber. Using a simplex armored cord for these links removes the unused leg entirely: less weight on the latch, nothing extra to dress, and no dark fiber inviting a wrong joint later.

Steel armor without extra bulk

At 3.0mm outside diameter this armored simplex cord is no thicker than a standard duplex jumper, yet the helical stainless tube inside gives it crush, pull and rodent resistance that ordinary patch leads lack. It dresses through the equivalent managers and rings as the rest of the frame; as a result, protection is added without changing the cabling practice.

Monitoring taps and test access

Optical taps, OTDR access points and permanent optical path monitoring all present single-fiber LC ports. A simplex armored cord is the right patch format for them: one strand, no spare leg, and steel protection for an optical path that is supposed to stay connected and unmonitored itself for years. For test access in public or industrial areas, the armored build additionally survives being temporarily routed through walkways during service work windows.

Length selection and customization

Standard size options are stocked for fast delivery: 1m (3ft), 2m (7ft), 3m (10ft), 5m (16ft), 10m (33ft), 15m (49ft), 20m (66ft) and 30m (98ft), covering the common rack-to-rack, access and frame connections this cord is built for. Non-standard lengths beyond this range are manufactured to order. In dense frames the measured length matters twice: once for the channel, and once given that surplus slack in a crowded manager hides the neighboring ports. Specifying the particular channel length avoids both the slack storage problem of an overlong cord and the strain risk of one that is too short.

Production testing and quality assurance

Each item is built with precision zirconia ferrule LC connectors and measured for insertion loss and return loss before packing; the 0.3dB and 50dB figures are verified per cord. Ferrule geometry is checked for stable physical contact across repeated matings, and the latch action is tested before packing.

Placing an Order and Factory Support

Quote against the LC UPC simplex armored product line with channel length and jacket rating stated. Hybrid builds, for example LC on one end and SC APC on the other, are provided as stock items or through the customized simplex armored program once the factory confirms the specification. Customers in the Philippines can include multi-site labeling or documentation requirements when requesting a project quotation.

 

About us

China Factory:No 168 Golden Ground Industrial Area;
Philippines Address:Makati City,Metro Manila, Philippines

Products catalogues

For products catalogue/data sheets or any general inquiry, please email info@huihongfiber.com and we will reply with details.

Customer Support

For customer support, please email sales@huihongfiber.com; our support team will get back to you as soon as possible.