Projects in the Philippines benefit from keeping the configuration, branch identification and installation requirement consistent across every participating site. This hybrid simplex armored patch cable pairs a flat-polished SC UPC connector on one end with an angled SC APC connector on the other, on a single OS2 9/125µm fiber protected by a helical stainless steel tube and blue 3.0mm riser-rated (OFCR) jacket. It exists for one recurring situation: equipment with UPC ports that must connect to an access plant terminated with APC interfaces. Project teams in the Philippines can carry this requirement into the site documentation used by each contractor.
| Connector Type | SC to SC |
|---|---|
| Polish Type | UPC to APC |
| Fiber Mode | OS2 9/125µm |
| Wavelength | 1310/1550nm |
| Fiber Count | Simplex |
| Fiber Grade | G.657.A1 (Compatible with G.652.D) |
| Min. Bend Radius (Fiber Cable) | 10/5D (Dynamic/Static) |
| Cable Outside Diameter (OD) | 3.0mm |
| Flame Rating | Riser (OFCR) |
| Construction Type | Single Armored, Stainless Steel Tube |
| Tensile Strength | 120/225N (Long/Short Term) |
| Insertion Loss | ≤0.3dB |
| Return Loss | ≥50dB (UPC) / ≥60dB (APC) |
| Operating Temperature | -20 to 70°C (-4 to 158°F) |
| Storage Temperature | -40 to 70°C (-40 to 158°F) |
Carrier access networks, PON plant and CATV infrastructure are overwhelmingly terminated with APC connectors, and at the same time a large share of customer-side and test equipment still ships with UPC interfaces. This hybrid cord joins the two directly in a single tested item, instead of leaving a mixed-polish adapter pair in the optical path where it adds loss and invites a mating mistake.
The industry convention is simple and worth enforcing: blue housings are UPC, green housings are APC. Mating a flat UPC ferrule against an angled APC ferrule leaves an air gap that ruins return loss and may permanently chip both end faces. On this cord the blue and green ends make the intended orientation obvious at a glance, even in a crowded enclosure.
Drop tails and customer-side jumpers are reconnected, stepped on and stuffed behind furniture-grade enclosures more than any other part of the plant. The helical steel tube inside the jacket lets this cord absorb that handling; as a result, the optical path survives the life of the deployment without conduit or protective sleeving.
Carrier access and CATV networks standardized on APC plant long ago, and at the same time much of the hardware that connects to them, from older CPE to field meters, still presents UPC. This cord bridges that boundary in central offices, hub sites and customer premises without an adapter pair in the middle. The blue and green housings keep the orientation unmistakable even when the enclosure is crowded with identical-looking jumpers.
Standard size options are stocked for fast delivery: 1m (3ft), 2m (7ft), 3m (10ft), 5m (16ft), 10m (33ft), 15m (49ft), 20m (66ft) and 30m (98ft), covering the common rack-to-rack, access and frame connections this cord is built for. Non-standard lengths beyond this range are manufactured to order. Access tails are easiest to dress at the measured length: order to the real distance from port to frame and no slack has to be hidden inside the enclosure. Specifying the particular channel length avoids both the slack storage problem of an overlong cord and the strain risk of one that is too short.
Each hybrid cord is terminated with precision zirconia ferrule SC connectors; the APC end is angle-verified and both end faces are geometry-checked. Insertion loss and return loss are measured through the finished item before packing; as a result, the published 0.3dB and 50/60dB figures are tested values on the cord that ships.
Quote against the SC UPC to SC APC simplex armored product line with the channel length and jacket rating stated. Other connector and polish combinations are provided through the customized simplex armored program once the factory confirms the requested specification. Customers in the Philippines can include multi-site labeling or documentation requirements when requesting a project quotation.