Projects in the Philippines benefit from keeping the configuration, branch identification and installation requirement consistent across every participating site. This duplex armored patch cable pairs flat-polished LC UPC connectors on one end with angled SC APC connectors on the other, on OS2 9/125µm single-mode fiber inside a helical stainless steel tube and a low smoke zero halogen jacket. It is built for carrier and access installations where LC-equipped optics must land on APC-terminated plant inside buildings that list LSZH cabling throughout.
| Connector Type | LC to SC |
|---|---|
| Polish Type | UPC to APC |
| Fiber Mode | OS2 9/125µm |
| Wavelength | 1310/1550nm |
| Fiber Count | Duplex |
| Fiber Grade | G.657.A1 (Compatible with G.652.D) |
| Min. Bend Radius (Fiber Cable) | 10/5D (Dynamic/Static) |
| Cable Outside Diameter (OD) | 3.0mm |
| Flame Rating | LSZH (Low Smoke Zero Halogen) |
| Construction Type | Single Armored, Stainless Steel Tube |
| Tensile Strength | 120/225N (Long/Short Term) |
| Insertion Loss | ≤0.3dB |
| Return Loss | ≥50dB (UPC) / ≥60dB (APC) |
| Operating Temperature | -20 to 70°C (-4 to 158°F) |
| Storage Temperature | -40 to 70°C (-40 to 158°F) |
PON and carrier access plant is terminated with angled APC connectors to keep reflections out of the configuration, and at the same time the optics that feed it increasingly ship with LC ports. This cord bridges the two in a single tested duplex item: LC UPC toward the hardware, green-bodied SC APC toward the frame, with no adapter pair adding loss in the middle.
Central offices, metro PoPs and in-building access rooms increasingly fall under the equivalent low smoke zero halogen rules as public buildings. This cord satisfies the jacket specification and the reflection specification at once; as a result, the compliance conversation is not intended to force a compromise on either the jacket or the polish.
Access frames and splitter cabinets are worked on constantly, and patch leads there are reseated, swung aside and redressed for years. The helical steel tube inside the LSZH jacket keeps the fibers safe through that service life, and the 3.0mm build still dresses through standard frame managers.
In-building PON distribution concentrates at splitter cabinets on each floor or zone, and those cabinets sit in corridors and service rooms where LSZH is specified. This cord patches LC-based OLT or test ports to the APC splitter frame within the equivalent jacket policy as the rest of the floor. The armored build tolerates the constant re-dressing that splitter cabinets see as subscribers are added.
Standard size options are stocked for fast delivery: 1m (3ft), 2m (7ft), 3m (10ft), 5m (16ft), 10m (33ft), 15m (49ft), 20m (66ft) and 30m (98ft), covering the common rack-to-rack, access and frame connections this cord is built for. Non-standard lengths beyond this range are manufactured to order. In carrier rooms the frame mounting point is fixed in the records; as a result, ordering to the documented channel length keeps the slack storage inside design limits. Specifying the particular channel length avoids both the slack storage problem of an overlong cord and the strain risk of one that is too short.
Each completed assembly is terminated with precision zirconia ferrules; the APC end is angle-verified and the UPC end geometry-checked. Insertion loss and return loss are measured through the finished duplex cord before packing; as a result, the 0.3dB insertion ceiling and the 50/60dB return figures are tested values on the delivered item.
Quote against the LC UPC to SC APC OS2 LSZH armored product line with the channel length stated and the LSZH need referenced. Other hybrid combinations, including simplex versions, are provided in the equivalent jacket configuration through the customized armored program. Customers in the Philippines can include multi-site labeling or documentation requirements when requesting a project quotation.